Extracorporeal membrane oxygenation versus counterpulsatile, pulsatile, and continuous left ventricular unloading for pediatric mechanical circulatory support.

Pediatr Crit Care Med

1Division of Cardiovascular Surgery, University of Pennsylvania, PA. 2MD/PhD Program, University of Louisville School of Medicine, Louisville, KY. 3Cardiovascular Innovation Institute, University of Louisville, Louisville, KY. 4Department of Bioengineering, University of Louisville, Louisville, KY. 5Department of Surgery, University of Louisville, Louisville, KY.

Published: November 2013

Objectives: Despite progress with adult ventricular assist devices, limited options exist to support pediatric patients with life-threatening heart disease. Extracorporeal membrane oxygenation remains the clinical standard. To characterize (patho)physiologic responses to different modes of mechanical unloading of the failing pediatric heart, extracorporeal membrane oxygenation was compared to intra-aortic balloon pump, pulsatile-flow ventricular assist device, or continuous-flow ventricular assist device support in a pediatric heart failure model.

Design: Experimental.

Setting: Large animal laboratory operating room.

Subjects: Yorkshire piglets (n = 47; 11.7 ± 2.6 kg).

Interventions: In piglets with coronary ligation-induced cardiac dysfunction, mechanical circulatory support devices were implanted and studied during maximum support.

Measurements And Main Results: Left ventricular, right ventricular, coronary, carotid, systemic arterial, and pulmonary arterial hemodynamics were measured with pressure and flow transducers. Myocardial oxygen consumption and total-body oxygen consumption were calculated from arterial, venous, and coronary sinus blood sampling. Blood flow was measured in 17 organs with microspheres. Paired Student t tests compared baseline and heart failure conditions. One-way repeated-measures analysis of variance compared heart failure, device support mode(s), and extracorporeal membrane oxygenation. Statistically significant (p < 0.05) findings included 1) an improved left ventricular blood supply/demand ratio during pulsatile-flow ventricular assist device, continuous-flow ventricular assist device, and extracorporeal membrane oxygenation but not intra-aortic balloon pump support, 2) an improved global myocardial blood supply/demand ratio during pulsatile-flow ventricular assist device and continuous-flow ventricular assist device but not intra-aortic balloon pump or extracorporeal membrane oxygenation support, and 3) diminished pulsatility during extracorporeal membrane oxygenation and continuous-flow ventricular assist device but not intra-aortic balloon pump and pulsatile-flow ventricular assist device support. A profile of systems-based responses was established for each type of support.

Conclusions: Each type of pediatric ventricular assist device provided hemodynamic support by unloading the heart with a different mechanism that created a unique profile of physiological changes. These data contribute novel, clinically relevant insight into pediatric mechanical circulatory support and establish an important resource for pediatric device development and patient selection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3913264PMC
http://dx.doi.org/10.1097/PCC.0b013e3182a551b0DOI Listing

Publication Analysis

Top Keywords

ventricular assist
40
assist device
36
extracorporeal membrane
28
membrane oxygenation
28
intra-aortic balloon
16
balloon pump
16
pulsatile-flow ventricular
16
continuous-flow ventricular
16
ventricular
14
left ventricular
12

Similar Publications

This study aimed to develop and validate a cost-effective, customizable patient-specific phantom for simulating external ventricular drain placement, combining image segmentation, 3-D printing and molding techniques. Two variations of the phantom were created based on patient MRI data, integrating a realistic skin layer with anatomical landmarks, a 3-D printed skull, an agarose polysaccharide gel brain, and a ventricular cavity. To validate the phantom, 15 neurosurgeons, residents, and physician assistants performed 30 EVD placements.

View Article and Find Full Text PDF

Background: Knowledge of the chemical composition of amyloid plaques and tau tangles at the earlier stages of Alzheimer's disease (AD) pathology is sparse. This is due to limited access to human brain during life and at the earlier stages of AD pathophysiology and technical limitations in quantifying amyloid and tau species at a subcellular level. Understanding the chemical composition of plaques and tangles, how rapidly they grow and what factors drive growth is important for developing and refining therapeutics.

View Article and Find Full Text PDF

Background: Left ventricular assist devices (LVADs) are utilized as a therapeutic option for patients with end-stage heart failure. While LVAD implantation can enhance survival rates and quality of life, the procedure has its risks, and postoperative complications are common. This review aims to investigate whether there is an association between living in a rural area and the incidence of postoperative complications or hospital readmissions following LVAD implantation, compared to urban LVAD recipients.

View Article and Find Full Text PDF

Cardiogenic shock (CS) in acute myocardial infarction (AMI) is a life-threatening syndrome characterized by systemic hypoperfusion that can quickly progress to multiorgan failure and death. Various devices and configurations of mechanical circulatory support (MCS) exist to support patients, each with unique pathophysiological characteristics. The Intra-aortic balloon pump can improve coronary perfusion, decrease afterload, and indirectly augment cardiac output.

View Article and Find Full Text PDF
Article Synopsis
  • Patients awaiting heart transplants often require colonoscopies due to bleeding or screening needs, but there's limited research on the safety of these procedures for individuals on inotropic medications or mechanical circulatory support.
  • A study was conducted from 2015 to 2021 with 92 heart failure patients undergoing colonoscopy while on advanced heart failure therapies, such as inotropes or mechanical devices.
  • Results indicated that the most common reason for colonoscopy was cancer screening, with significant findings including 8% of screening procedures revealing advanced adenomas and 17% of bleeding-related colonoscopies identifying sources needing intervention, but no major complications related to anesthesia were reported.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!