AI Article Synopsis

  • Noninvasive imaging techniques for characterizing tissue engineering scaffolds face challenges like limited tissue penetration and destructive methods; traditional histological analysis isn’t suitable for longitudinal data.
  • This study investigates the use of ultrasound-coregistered photoacoustic imaging to noninvasively characterize poly(lactic-co-glycolic acid) (PLGA) scaffolds and blood oxygen levels.
  • While PLGA scaffolds were not detectable with photoacoustic imaging, the addition of single-walled carbon nanotubes (SWCNTs) allowed for better imaging, significantly improving localization and providing valuable data on oxygen saturation in both ex vivo and in vivo setups.

Article Abstract

Preclinical, noninvasive imaging of tissue engineering polymeric scaffold structure and/or the physiological processes such as blood oxygenation remains a challenge. In vitro or ex vivo, the widely used scaffold characterization modalities such as porosimetry, electron or optical microscopy, and X-ray microcomputed tomography have limitations or disadvantages-some are invasive or destructive, others have limited tissue penetration (few hundred micrometers) and/or show poor contrast under physiological conditions. Postmortem histological analysis, the most robust technique for the evaluation of neovascularization is obviously not appropriate for acquiring physiological or longitudinal data. In this study, we have explored the potential of ultrasound (US)-coregistered photoacoustic (PA) imaging as a noninvasive multimodal imaging modality to overcome some of the above challenges and/or provide complementary information. US-PA imaging was employed to characterize poly(lactic-co-glycolic acid) (PLGA) polymer scaffolds or single-walled carbon nanotube (SWCNT)-incorporated PLGA (SWCNT-PLGA) polymer scaffolds as well as blood oxygen saturation within and around the scaffolds. Ex vivo, PLGA and SWCNT-PLGA scaffolds were placed at 0.5, 2, and 6 mm depths in chicken breast tissues. PLGA scaffolds could be localized with US imaging, but generate no PA signal (excitation wavelengths 680 and 780 nm). SWCNT-PLGA scaffolds generated strong PA signals at both wavelengths due to the presence of the SWCNTs and could be localized with both US and PA imaging depths between 0.5-6 mm (lateral resolution = 90 μm, axial resolution = 40 μm). In vivo, PLGA and SWCNT-PLGA scaffolds were implanted in subcutaneous pockets at 2 mm depth in rats, and imaged at 7 and 14 days postsurgery. The anatomical position of both the scaffolds could be determined from the US images. Only SWCNT-PLGA scaffolds could be easily detected in the US-PA images. SWCNT-PLGA scaffolds had significant four times higher PA signal intensity compared with the surrounding tissue and PLGA scaffolds. In vivo blood oxygen saturation maps around and within the PLGA scaffolds could be obtained by PA imaging. There was no significant difference in oxygen saturation for the PLGA scaffolds at the two time points. The blood oxygen saturation maps complemented the histological analysis of neovascularization of the PLGA scaffolds.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4005489PMC
http://dx.doi.org/10.1089/ten.TEC.2013.0203DOI Listing

Publication Analysis

Top Keywords

oxygen saturation
20
swcnt-plga scaffolds
20
plga scaffolds
20
scaffolds
16
blood oxygen
16
plga swcnt-plga
12
plga
9
imaging
8
imaging tissue
8
tissue engineering
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!