A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Left ventricular mass regression after sutureless implantation of the Perceval S aortic valve bioprosthesis: preliminary results. | LitMetric

Objectives: Left ventricular (LV) hypertrophy in aortic stenosis (AS) is considered a compensatory response helping maintain systolic function, but constitutes a risk factor for cardiac morbidity and mortality. The aim of this study was to assess the degree of LV mass regression after sutureless implantation of the Perceval S aortic valve bioprosthesis (Sorin Group, Saluggia, Italy).

Methods: Between March 2010 and July 2012, 78 patients with symptomatic AS underwent isolated aortic valve replacement (AVR) with the Perceval bioprosthesis. Mean age was 77.1 ± 5.3 years, 46 patients were female (59%) and mean logistic EuroSCORE was 11 ± 7.5%. Echocardiography was performed preoperatively, at discharge, and at follow-up (mean 13.5 ± 7.3 months). LV mass was calculated using the Devereux formula and indexed to body surface area.

Results: There was 1 in-hospital non-cardiac death and 3 late deaths. LV mass index decreased from 148.4 ± 46 g/m(2) at baseline to 119.7 ± 38.5 g/m(2) at follow-up (P = 0.002). No significant changes were observed in LV hypertrophy and/or relative wall thickness >0.42 as well as in LV ejection fraction. Mean aortic gradient decreased from 49.5 ± 15.8 mmHg at baseline to 11.6 ± 5.1 mmHg at discharge and 8.3 ± 4.4 mmHg at follow-up (P < 0.001), resulting in significant clinical improvement. No moderate or severe paravalvular leakage was observed at discharge and at follow-up.

Conclusions: In AS patients, isolated AVR with the Perceval sutureless bioprosthesis is associated with significant LV mass regression at 1-year follow-up. However, longer-term follow-up is necessary to confirm these findings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3867027PMC
http://dx.doi.org/10.1093/icvts/ivt362DOI Listing

Publication Analysis

Top Keywords

mass regression
12
aortic valve
12
left ventricular
8
regression sutureless
8
sutureless implantation
8
implantation perceval
8
perceval aortic
8
valve bioprosthesis
8
avr perceval
8
mass
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!