Coincident electron-ion detection after photoionization in a "reaction microscope" is a very powerful tool to study atomic and molecular dynamics. However, the implementation of this tool in the field of attosecond science has so far been rather limited, due to the lack of high repetition rate laser sources capable of delivering few-cycle pulses with sufficient energy per pulse. In this article, the development of a Non-collinear Optical Parametric Amplifier (NOPA) capable of delivering Carrier-Envelope Phase (CEP) stable pulses with sub-6 fs duration and pulse energies in the few-µJ range is presented. The potential of combining the high repetition rate source and a reaction microscope operating at this high frequency is demonstrated in a proof-of-principle experiment on strong field ionization of Ar atoms.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.21.022671DOI Listing

Publication Analysis

Top Keywords

carrier-envelope phase
8
few-cycle pulses
8
high repetition
8
repetition rate
8
capable delivering
8
phase stable
4
stable few-cycle
4
pulses 400
4
400 khz
4
khz electron-ion
4

Similar Publications

We describe improved methods for locating the fixed point of an optical frequency comb. Two continuous-wave lasers are locked to a reference frequency comb and track the optical phase of a second comb-under-test (CUT) at two points separated by approximately 1.6 THz.

View Article and Find Full Text PDF

Attosecond science has demonstrated that electrons can be controlled on the sub-cycle time scale of an optical waveform, paving the way towards optical frequency electronics. However, these experiments historically relied on high-energy laser pulses and detection not suitable for microelectronic integration. For practical optical frequency electronics, a system suitable for integration and capable of generating detectable signals with low pulse energies is needed.

View Article and Find Full Text PDF

The carrier-envelope phase (CEP) of a laser pulse plays a crucial role in laser-matter interactions. The inherent shot-to-shot instability of the CEP necessitates single-shot detection, which is not only vital for stabilizing the CEP but also for observing ultrafast phenomena that conventional averaging techniques cannot resolve. In this study, we demonstrate a novel approach utilizing strong-field ionization in ambient air for single-shot CEP measurement.

View Article and Find Full Text PDF

In this paper, we propose a high-precision dual-comb ranging (DCR) method for short-distance measurement, avoiding carrier-envelope-offset locking. Cross-polarization detection is introduced, which makes better use of the intrinsic coherence of interferogram pairs over a short distance. We analyze the noise in the DCR system and propose a carrier-wave phase difference (CPD) calculation algorithm based on centroid extraction.

View Article and Find Full Text PDF

We propose a novel, to our knowledge, method for modulating and real-time monitoring of the carrier-envelope phase (CEP) of terahertz (THz) pulses. CEP is an essential parameter in the interaction of THz waves with matter due to the difference in temporal symmetry when the carrier is extended for several cycles. CEP can be continuously modulated at full range with high speed by oscillating the optical path length of the Michelson interferometer under 1 µm, as confirmed by electro-optic (EO) sampling.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!