Text-to-speech technology effects on reading rate and comprehension by adults with traumatic brain injury.

Brain Inj

Department of Special Education and Communication Disorders, University of Nebraska-Lincoln, Lincoln, NE , USA and.

Published: June 2014

Objective: This study's purpose was to examine the comprehension, rate and perceptions and reading preferences of adults with severe traumatic brain injury (TBI) when reading passages with and without computerized text-to-speech (TTS) support.

Design And Methods: Nine adults with severe TBI read 24 passages in two conditions: with and without TTS support. The researchers compared reading rate and comprehension accuracy across conditions. Also, participants rated their perceived performance and reading preferences via a follow-up questionnaire.

Results: Comparison to normative data revealed that all nine participants read slower than average neurotypical readers. As a group, participants read significantly faster with TTS support than without such support, even though the TTS reading rate was roughly comparable to the oral rather than silent reading rate of neurotypical adults. No significant differences in comprehension resulted between the two conditions. Over half of the participants preferred the TTS condition over the no-TTS condition. In general, participants were inaccurate in judging their relative reading rates and comprehension accuracy across conditions.

Conclusions: TTS may improve reading efficiency without compromising reading comprehension accuracy for adults with TBI. Given this finding, some survivors may find use of TTS technology contributes to increased participation in and efficiency when performing reading activities.

Download full-text PDF

Source
http://dx.doi.org/10.3109/02699052.2013.823649DOI Listing

Publication Analysis

Top Keywords

reading rate
16
comprehension accuracy
12
reading
11
rate comprehension
8
traumatic brain
8
brain injury
8
reading preferences
8
adults severe
8
tts support
8
participants read
8

Similar Publications

Background: Nocturnal blood pressure dipping is crucial for cardiovascular health, but the effect of exercise on this phenomenon is not well understood. This study aims to investigate how a single session of aerobic exercise impacts nocturnal blood pressure dipping in individuals with hypertension who are on medication.

Methods: Twenty hypertensive adults (67 ± 16 years) participated in a randomised, parallel-group clinical trial.

View Article and Find Full Text PDF

Purpose: To investigate the impact of artificial intelligence (AI) reading digital mammograms in increasing the chance of detecting missed breast cancer, by studying the AI- flagged early morphology indictors, overlooked by the radiologist, and correlating them with the missed cancer pathology types.

Methods And Materials: Mammograms done in 2020-2023, presenting breast carcinomas (n = 1998), were analyzed in concordance with the prior one year's result (2019-2022) assumed negative or benign. Present mammograms reviewed for the descriptors: asymmetry, distortion, mass, and microcalcifications.

View Article and Find Full Text PDF

The lack of thematic continuity in dreams with scene and plot discontinuities.

Sleep Adv

December 2024

EPISTEME Research and Strategy, Brooklyn, NY, USA.

A central tenet of Freudian dream theory holds that there is thematic coherence within all dreams, even those containing scene and plot discontinuities. While other models support varying degrees of dream coherence, none address the question of how, or even whether, coherence can be identified in dreams with such discontinuities. Here, we objectively test the ability of judges to evaluate the coherence of individual dream narratives.

View Article and Find Full Text PDF

The aim of our study was to evaluate the specific performance of an artificial intelligence (AI) algorithm for lung nodule detection in chest radiography for a larger number of nodules of different sizes and densities using a standardized phantom approach. A total of 450 nodules with varying density (d1 to d3) and size (3, 5, 8, 10 and 12 mm) were inserted in a Lungman phantom at various locations. Radiographic images with varying projections were acquired and processed using the AI algorithm for nodule detection.

View Article and Find Full Text PDF

This study aims to enhance positron emission tomography (PET) imaging systems by developing a continuous depth-of-interaction (DOI) measurement technique using a single-ended readout. Our primary focus is on reducing the number of readout channels in the scintillation detectors while maintaining accurate DOI estimations, using a high-pass filter-based signal multiplexing technique combined with artificial neural networks (ANNs). Approach: Instead of reading out all 64 signals from an 8×8 silicon photomultiplier array for DOI estimation, the proposed method technique reduces the signals into just four channels by applying high-pass filters with different time constants.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!