Introduction: Left atrial catheter ablation is useful as symptomatic treatment in selected patients with atrial fibrillation (AF). Evaluation requires measurement of arrhythmia-related symptoms. Many of the published protocols have drawbacks and have been used in AF only, with no possible comparison to other ablations that compete for the same resources. U22 is a published protocol that quantifies paroxysmal tachycardia symptoms through scales with 11 answer alternatives, translated into discrete numerical scales 0-10. It has been shown to reflect the clinical improvement after ablation of supraventricular tachycardia. Here we report the use of U22 in measuring improvement after catheter ablation for AF.
Material And Methods: A total of 105 patients underwent first-time ablation for AF and answered U22 and SF-36 forms at baseline and follow-up 304 (SD 121) days after ablation. Independently, the patients underwent a clinical follow-up. All decisions regarding medication and reablation were taken without knowledge of the symptom scores. Results. The U22 scores for well-being, arrhythmia as cause for impaired well-being, derived time-aspect score for arrhythmia, and discomfort during attack detected relevant improvements of symptoms after the ablation. U22 showed larger improvement in patients undergoing only one procedure than in patients who later underwent repeated interventions, thus reflecting the independent clinical decision for reablation.
Conclusion: U22 quantifies the symptomatic improvement after AF ablation with adequate internal consistency and construct validity. U22 mirrors aspects of the arrhythmia symptomatology other than SF-36.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4190885 | PMC |
http://dx.doi.org/10.3109/03009734.2013.821190 | DOI Listing |
Front Cardiovasc Med
January 2025
Department of Cardiology, General Regional Hospital "F. Miulli", Bari, Italy.
Background: Cardioneuroablation (CNA) is a new approach to treat reflex syncope and functional bradyarrhytmias caused by autonomic imbalance. We report our experience using CNA.
Method: From September 2022 to July 2023, we took care of 21 patients (mean age 42 ± 21 years; 62% male) affected by reflex syncope or functional bradyarrhythmias.
Eur Cardiol
December 2024
Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen Copenhagen, Denmark.
Despite significant advances in its management, AF remains a major healthcare burden affecting millions of individuals. Rhythm control with antiarrhythmic drugs or catheter ablation has been shown to improve symptoms and outcomes in AF patients, but current treatment options have limited efficacy and/or significant side-effects. Novel mechanism-based approaches could potentially be more effective, enabling improved therapeutic strategies for managing AF.
View Article and Find Full Text PDFThe complex signal identification function of CARTO version 8 enables quantitative evaluation of local potential fractionation. We present a case where this advanced technology successfully identified non-pulmonary vein foci associated with fractionated potentials during sinus rhythm.
View Article and Find Full Text PDFRev Port Cardiol
January 2025
Cardiology Department, Hospital Santa Cruz, Centro Hospitalar Lisboa Ocidental, Lisbon, Portugal.
Introduction And Objectives: Pulmonary vein (PV) isolation is one of the cornerstones of rhythm-control therapy for symptomatic atrial fibrillation (AF) patients. Pulsed field ablation (PFA) is a novel ablation modality that involves the application of electrical pulses causing cellular death, and it has preferential tissue specificity. In this study, we aimed to share a one-year single center experience of AF ablation with PFA.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Department of Cardiology, Saitama Medical University, International Medical Center, Hidaka, Saitama, Japan.
Background: The IntellaNav MiFi OI catheter (MiFi) is equipped with a sensor for local impedance (LI) monitoring and three mini-electrodes. In this study, we investigated the target LI values for a successful pulmonary vein isolation (PVI) under the pacing and ablation technique using the MiFi catheter.
Methods: Twenty-seven patients underwent PVI using the MiFi catheter under mini electrode pacing from the MiFi catheter.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!