Aims: Reference ranges of ascending aorta diameters (AAoD) for two-dimensional echocardiography (2DE) using inner edge (IE) convention are lacking, preventing the comparison of AAoD measurements by 2DE with those obtained by other imaging modalities.
Methods And Results: We used harmonic imaging 2DE to prospectively study 218 healthy volunteers (56% women, 42 ± 15 years, 18-80 years). Measurements were performed at the level of aortic root (AoR), sinotubular junction (STJ), and proximal tubular portion (TAo, 1 cm from the STJ) using both leading edge (LE) and IE conventions at end-diastole and end-systole. Feasibility of AAoD measurements between end-diastole and end-systole was similar at AoR and STJ levels, but it was significantly different at TAo level (82 vs. 96%, respectively, P < 0.0001). Ascending aorta diameters indexed to height were larger in men than in women (P < 0.0001). After adjusting for the effect of gender, only age and body surface area (BSA) were independent predictors of AAoD at multivariable analysis. Average end-diastolic AoR, STJ, and TAo diameters measured using IE convention were similar between genders (17 ± 2, 15 ± 2, and 15 ± 2 mm/m(2), respectively). Corresponding AAoD measured using the LE convention were 18 ± 2, 16 ± 2, and 17 ± 4 mm/m(2), respectively. On average, the end-systolic AAoD measured using LE were 2 mm larger than those performed using IE or at end-diastole. Mean aortic wall thickness was 2.4 ± 0.8 mm.
Conclusion: End-diastolic AAoD measured using IE were significantly smaller than those obtained either using LE convention or at end-systole. Gender-specific reference values for AAoD indexed for BSA should be used to identify ascending aorta pathology.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/ehjci/jet173 | DOI Listing |
J Med Genet
January 2025
Center of Medical Genetics, University of Antwerp and Antwerp University Hospital, Antwerp, Belgium.
Background: Individuals harbouring pathogenic variants are at risk for aneurysms/dissections throughout the arterial tree. Based on prior reports of sex differences in thoracic aortic aneurysm/dissection, we investigated the sexual dimorphism for vascular events in variant-harbouring patients.
Methods: We analysed two large pedigrees comprising 84 individuals segregating pathogenic missense variants affecting the same p.
J Invasive Cardiol
December 2024
Division of Cardiology, Stony Brook University Hospital, Stony Brook, New York.
A A Pract
January 2025
Department of Anesthesiology, University of Kansas Medical Center, Kansas City, Kansas.
Transcatheter aortic valve replacement (TAVR) is a common treatment for severe aortic stenosis (AS), but it carries the risk of severe complications, including device embolization. We present a case of a TAVR valve embolization into the left ventricular outflow tract (LVOT), diagnosed with transesophageal echocardiography (TEE) shortly after device deployment. The dislodged valve was successfully retrieved from the LVOT into the aorta, flattened, and stabilized with a thoracic endovascular aneurysm repair (TEVAR) stent, enabling the successful implantation of a new TAVR valve.
View Article and Find Full Text PDFArterioscler Thromb Vasc Biol
January 2025
Division of Cardiology, Department of Medicine, University of Washington (S.S., S.J., N.S., C.Y.L., L.L., D.A.D.).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!