  • The study aimed to compare the performance and optical qualities of three cystoscopes: a high-definition distal sensor (HD-DS), a standard-definition distal sensor (SD-DS), and a standard fiberoptic (FO) model.
  • Results indicated that the HD-DS had superior resolution, color accuracy, and depth of field compared to the SD-DS and FO, along with better active deflection and irrigation flow capabilities.
  • Participants noted that the HD-DS provided enhanced visualization in various conditions, warranting further clinical evaluation.

Article Abstract

Objective: To evaluate performance characteristics and optics of a new generation high-definition distal sensor (HD-DS) flexible cystoscope, a standard-definition distal sensor (SD-DS) cystoscope, and a standard fiberoptic (FO) cystoscope.

Methods: Three new cystoscopes (HD-DS, SD-DS, and FO) were compared for active deflection, irrigation flow, and optical characteristics. Each cystoscope was evaluated with an empty working channel and with various accessories. Optical characteristics (resolution, grayscale imaging, color representation, depth of field, and image brightness) were measured using United States Air Force (USAF)/Edmund Optics test targets and illumination meter. We digitally recorded a porcine cystoscopy in both clear and blood fields, with subsequent video analysis by 8 surgeons via questionnaire.

Results: The HD-DS had a higher resolution than the SD-DS and the FO at both 20 mm (6.35 vs 4.00 vs 2.24 line pairs/mm) and 10 mm (14.3 vs 7.13 vs 4.00 line pairs/mm) evaluations, respectively (P <.001 and P <.001). Color representation and depth of field (P = .001 and P <.001) were better in the HD-DS. When compared to the FO, the HD-DS and SD-DS demonstrated superior deflection up and irrigant flow with and without accessory present in the working channel, whereas image brightness was superior in the FO (P <.001, P = .001, and P <.001, respectively). Observers deemed the HD-DS cystoscope superior in visualization in clear and bloody fields, as well as for illumination.

Conclusion: The new HD-DS provided significantly improved visualization in a clear and a bloody field, resolution, color representation, and depth of field compared to SD-DS and FO. Clinical correlation of these findings is pending.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.urology.2013.06.033DOI Listing

Publication Analysis

Top Keywords

distal sensor
16
definition cystoscope
8
optical characteristics
8
cystoscope
6
comparison optics
4
optics performance
4
distal
4
performance distal
4
sensor
4
sensor high
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!