Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Hydroxylated polybrominated diphenyl ethers (OH-PBDEs) have been identified as metabolites of polybrominated diphenyl ethers (PBDEs) and/or as natural products. The OH-PBDEs and polybromophenols have come into focus over the last decade due to their abundance in biota and their potential adverse health effects. The present recovery study aims to validate a commonly used method (published by Hovander et al. 2000) for OH-PBDE analysis in human plasma. Further, the authors intended to determine the method's applicability to serum/plasma matrices from other species than humans. The investigated matrices were human plasma, cat serum, herring- and long-tailed duck plasma. The recovery study included nine OH-PBDEs, four polybromophenols and three methoxylated PBDEs (MeO-PBDEs). Five replicates of each matrix were spiked with these compounds at two dose levels; a low dose (0.5 ng) and a high dose (5 ng) and were cleaned up according to the Hovander method. The recovery of OH-PBDEs and polybromophenols in human plasma and cat serum were high and reproducible at both dose levels whereas the recovery for herring and long-tailed duck plasma were low and insufficient with great variability amongst OH-PBDE congeners at both dose levels. Our data show that the method can be fully applied to matrices like human plasma and cat serum but not for herring and long-tailed duck plasma without further method development. Hence care needs to be taken when applying the method onto other blood matrices without validation since the present study have demonstrated that the recoveries may differ amongst OH-PBDE congeners and specie.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chemosphere.2013.09.020 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!