Quadrature phase interferometer for high resolution force spectroscopy.

Rev Sci Instrum

Laboratoire de physique, Université de Lyon, ENS Lyon, CNRS, Lyon 69364, France.

Published: September 2013

In this article, we present a deflection measurement setup for Atomic Force Microscopy (AFM). It is based on a quadrature phase differential interferometer: we measure the optical path difference between a laser beam reflecting above the cantilever tip and a reference beam reflecting on the static base of the sensor. A design with very low environmental susceptibility and another allowing calibrated measurements on a wide spectral range are described. Both enable a very high resolution (down to 2.5×10(-15) m/√Hz), illustrated by thermal noise measurements on AFM cantilevers. They present an excellent long-term stability and a constant sensitivity independent of the optical phase of the interferometer. A quick review shows that our precision is equaling or out-performing the best results reported in the literature, but for a much larger deflection range, up to a few μm.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4819743DOI Listing

Publication Analysis

Top Keywords

quadrature phase
8
phase interferometer
8
high resolution
8
beam reflecting
8
interferometer high
4
resolution force
4
force spectroscopy
4
spectroscopy article
4
article deflection
4
deflection measurement
4

Similar Publications

Rate-Compatible, Bandwidth-Efficient, Low-Density Parity-Check (LDPC) Codes for Aeronautical Telemetry.

Entropy (Basel)

November 2024

Department of Electrical Engineering & Computer Science, University of Kansas, Lawrence, KS 66045, USA.

Low-density parity-check (LDPC) codes form part of the IRIG-106 standard and have been successfully deployed for the Telemetry Group version of shaped-offset quadrature phase shift keying (SOQPSK-TG) modulation. Recently, LDPC code solutions have been proposed and optimized for continuous phase modulations (CPMs), including pulse code modulation/frequency modulation (PCM/FM) and the multi-h CPM developed by the Advanced-Range TeleMetry program (ARTM CPM), the latter of which was shown to perform around one dB from channel capacity. In this paper, we consider the effect of the random puncturing and shortening of these LDPC codes to further improve spectrum efficiency.

View Article and Find Full Text PDF

We developed a technique allowing the direct observation of photoinduced charge-transfer states (CTSs)-the weakly coupled electron-hole pairs preceding the completely separated charges in organic photovoltaic (OPV) blends. Quadrature detection of the electron spin echo (ESE) signal enables the observation of an out-of-phase ESE signal of CTS. The out-of-phase Electron-Electron Double Resonance (ELDOR) allows measuring electron-hole distance distributions within CTS and its temporal evolution in the microsecond range.

View Article and Find Full Text PDF

We experimentally demonstrate a cost-effective dual-polarization quadrature phase shift keying (DP-QPSK) coherent passive optical network (PON) system that operates at 100 Gbits/s/λ. This system utilizes distributed feedback lasers (DFBs) and a carrier recovery algorithm facilitated by a bifunctional frequency-domain pilot tone (FPT). To reduce costs in coherent PON implementations, low-cost DFBs are employed as the sole light sources, replacing the more expensive external cavity lasers (ECLs) at both the optical line terminal (OLT) and the optical network units (ONUs).

View Article and Find Full Text PDF

Ultrasound imaging with flexible transducers based on real-time and high-accuracy shape estimation.

Ultrasonics

December 2024

Department of Biomedical Engineering, Fudan University, Shanghai 200438, China; Key Laboratory of Medical Imaging Computing and Computer Assisted Intervention of Shanghai, Shanghai 200032, China. Electronic address:

Article Synopsis
  • Ultrasound imaging with flexible transducers needs precise shape geometry for effective beamforming, but traditional methods for shape estimation are costly in terms of computation time and often lack accuracy.
  • A new deep-learning method, FlexSANet, offers a fast and accurate approach by demodulating I/Q data and using a sparse processing mechanism to reduce estimation time.
  • Evaluations show that FlexSANet achieves high-quality imaging with minimal error in shape estimation (less than 1/8 wavelengths), and demonstrates promising clinical application potential with an estimation time of just 0.12 seconds.
View Article and Find Full Text PDF

We propose a surface-normal dual-polarization in-phase and quadrature modulator (DP-IQM) that employs a thin dielectric metasurface (MS) layer inserted on a high-speed electro-absorptive modulator array. The metasurface provides the functionalities of all the passive components necessary for a DP-IQM, including a polarization beam splitter/combiner and an interferometric circuit, to a normal-incident beam. A dielectric metasurface composed of silicon nanoposts is designed and fabricated to experimentally demonstrate polarization and beam splitting functionalities with a phase error of less than 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!