Cost-effectiveness of catheter ablation for rhythm control of atrial fibrillation.

Int J Vasc Med

PATH Research Institute, McMaster University, Suite 2000, 25 Main Street West, Hamilton, ON, Canada L8P 1H1 ; Department of Clinical Epidemiology & Biostatistics, McMaster University, Hamilton, ON, Canada L8S 4L8.

Published: October 2013

Objective. The objective of this study is to evaluate the cost-effectiveness of catheter ablation for rhythm control compared to antiarrhythmic drug (AAD) therapy in patients with atrial fibrillation (AF) who have previously failed on an AAD. Methods. An economic model was developed to compare (1) catheter ablation and (2) AAD (amiodarone 200 mg/day). At the end of the initial 12 month phase of the model, patients are classified as being in normal sinus rhythm or with AF, based on data from a meta-analysis. In the 5-year Markov phase of the model, patients are at risk of ischemic stroke each 3-month model cycle. Results. The model estimated that, compared to the AAD strategy, ablation had $8,539 higher costs, 0.033 fewer strokes, and 0.144 more QALYS over the 5-year time horizon. The incremental cost per QALY of ablation compared to AAD was estimated to be $59,194. The probability of ablation being cost-effective for willingness to pay thresholds of $50,000 and $100,000 was estimated to be 0.89 and 0.90, respectively. Conclusion. Based on current evidence, pulmonary vein ablation for treatment of AF is cost-effective if decision makers willingness to pay for a QALY is $59,194 or higher.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3781920PMC
http://dx.doi.org/10.1155/2013/262809DOI Listing

Publication Analysis

Top Keywords

catheter ablation
12
cost-effectiveness catheter
8
ablation rhythm
8
rhythm control
8
atrial fibrillation
8
phase model
8
model patients
8
compared aad
8
willingness pay
8
ablation
7

Similar Publications

Background: The IntellaNav MiFi OI catheter (MiFi) is equipped with a sensor for local impedance (LI) monitoring and three mini-electrodes. In this study, we investigated the target LI values for a successful pulmonary vein isolation (PVI) under the pacing and ablation technique using the MiFi catheter.

Methods: Twenty-seven patients underwent PVI using the MiFi catheter under mini electrode pacing from the MiFi catheter.

View Article and Find Full Text PDF

Background: Concurrent Micra leadless pacemaker (Medtronic, Minneapolis, Minnesota) implantation and atrioventricular node (AVN) ablation has been shown to be feasible and safe in patients with symptomatic, drug-refractory atrial fibrillation (AF). However, major complications within the 30 days after concurrent Micra implantation and AVN ablation have been reported. We evaluated the efficacy and safety of the concurrent procedure at our institution.

View Article and Find Full Text PDF

Objective: The Vizigo sheath, a novel visualizable steerable sheath, has been utilized effectively in the clinical management of atrial fibrillation. However, its application in the ablation of typical atrial flutter (AFL) remains unexplored. This study aims to evaluate and compare the efficacy and safety of the Vizigo sheath against a conventional fixed sheath during catheter ablation for typical AFL.

View Article and Find Full Text PDF

In Vivo Tissue Temperature Characteristics of Contact Force Catheter With a Mesh-Shaped Irrigation Tip: A Porcine Study.

Pacing Clin Electrophysiol

January 2025

Section of Laboratory for Animal Experiments, Institute of Medical Science, Medical Research Support Center, Nihon University, School of Medicine, Tokyo, Japan.

Background: Neither the actual in vivo tissue temperatures reached with a novel contact force sensing catheter with a mesh-shaped irrigation tip (TactiFlex SE, Abbott) nor the safety profile has been elucidated.

Methods: In a porcine model (n = 8), thermocouples were implanted epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava following a right thoracotomy. After chest closure, endocardial ablation was conducted near the thermocouples under fluoroscopic guidance.

View Article and Find Full Text PDF

Introduction: Freedom from recurrences of atrial tachyarrhythmia (ATA) is suboptimal after pulmonary vein isolation (PVI) in patients with persistent atrial fibrillation (PsAF). This sub-analysis from the Cryo Global Registry sought to investigate predictors of ablation success after PVI using cryoballoon ablation (CBA) for PsAF.

Methods And Results: ATA recurrence was defined as ≥ 30 s recurrence of atrial fibrillation, atrial flutter or atrial tachycardia after a 90-day blanking period and through 12-months.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!