Routine micromethod for the determination of vitamin K1 in human plasma.

Ther Drug Monit

*Department of Clinical Pharmacology, University Medical Centre of the Georg August University Göttingen, Göttingen, Germany; and †Institute of Pharmacology of Natural Products and Clinical Pharmacology, University of Ulm, Ulm, Germany.

Published: December 2013

Background: A selective and sensitive high-performance liquid chromatographic method with fluorescence detection after postcolumn reduction is described for the routine measurement of vitamin K1 in plasma samples of 100 µL of volume.

Methods: Liquid-liquid extraction was used for the sample preparation with vitamin K2 as an internal standard. For the chromatographic separation, a standard C18 column was applied. The calibration range used was from 2 to 500 ng/mL.

Results: At the low level (5 ng/mL), a coefficient of variation of 14.9% was observed interday in the quality control samples, whereas at the intermediate (50 ng/mL) and high (200 ng/mL) levels such of 6.8% and 8.7% were found.

Conclusions: The method has proven robust and convenient for the analysis of samples from clinical pharmacological studies.

Download full-text PDF

Source
http://dx.doi.org/10.1097/FTD.0b013e31828eff38DOI Listing

Publication Analysis

Top Keywords

routine micromethod
4
micromethod determination
4
determination vitamin
4
vitamin human
4
human plasma
4
plasma background
4
background selective
4
selective sensitive
4
sensitive high-performance
4
high-performance liquid
4

Similar Publications

Introduction: Exposure to normal or variably expressed RhD antigens in an antigen-negative individual can elicit an immune response and lead to the formation of clinically significant anti-D alloantibodies. We present the case of anti-D alloimmunization by DEL variant missed in routine blood donor screening.

Material And Methods: Blood donors were typed for D antigen using the direct serologic micromethod.

View Article and Find Full Text PDF

Background: Congenital Trypanosoma cruzi infection accounts for an estimated 22% of new cases of Chagas disease in Latin America. However, neonatal diagnosis is challenging, as 9-month follow-up for immunoglobulin G testing is poor, quantitative polymerase chain reaction (qPCR) analysis is not routinely performed, and the micromethod misses ≥40% of congenital infections.

Methods: Biorepository samples from new mothers and their infants from Piura, Peru, (an area of nonendemicity), and Santa Cruz, Bolivia (an area of endemicity) were accessed.

View Article and Find Full Text PDF

Background: Congenital Trypanosoma cruzi transmission is now estimated to account for 22% of new infections, representing a significant public health problem across Latin America and internationally. Treatment during infancy is highly efficacious and well tolerated, but current assays for early detection fail to detect >50% of infected neonates, and 9-month follow-up is low.

Methods: Women who presented for delivery at 2 urban hospitals in Santa Cruz Department, Bolivia, were screened by rapid test.

View Article and Find Full Text PDF

Target fortification of breast milk: levels of fat, protein or lactose are not related.

Acta Paediatr

January 2015

Division of Neonatology, Department of Pediatrics, McMaster University, Hamilton, ON, Canada.

Aim: Target fortification (TFO) of breast milk has the potential to improve the nutritional outcomes of preterm infants. However, the primary logistic constraint in introducing TFO is analysers that rapidly and accurately analyse macronutrients (fat, protein and lactose). In this prospective observational study, we aim to evaluate whether the levels of fat, protein and carbohydrate could be predicted from one key macronutrient.

View Article and Find Full Text PDF

Routine micromethod for the determination of vitamin K1 in human plasma.

Ther Drug Monit

December 2013

*Department of Clinical Pharmacology, University Medical Centre of the Georg August University Göttingen, Göttingen, Germany; and †Institute of Pharmacology of Natural Products and Clinical Pharmacology, University of Ulm, Ulm, Germany.

Background: A selective and sensitive high-performance liquid chromatographic method with fluorescence detection after postcolumn reduction is described for the routine measurement of vitamin K1 in plasma samples of 100 µL of volume.

Methods: Liquid-liquid extraction was used for the sample preparation with vitamin K2 as an internal standard. For the chromatographic separation, a standard C18 column was applied.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!