A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Diffusion-weighted magnetic resonance imaging of the pancreas: diagnostic benefit from an intravoxel incoherent motion model-based 3 b-value analysis. | LitMetric

Diffusion-weighted magnetic resonance imaging of the pancreas: diagnostic benefit from an intravoxel incoherent motion model-based 3 b-value analysis.

Invest Radiol

From the *Department of Radiology, University of Bonn, Bonn; †Institute of Medical Engineering, Ruhr-University Bochum, Bochum; ‡Department of Internal Medicine 3, University of Bonn, Bonn, Germany; and §Philips Healthcare, Best, The Netherlands.

Published: February 2014

Objectives: The objective of this study was to evaluate the diagnostic benefit of an intravoxel incoherent motion (IVIM) model-based characterization of pancreatic masses from diffusion-weighted imaging (DWI) with 3 b values.

Materials And Methods: This retrospective study had an approval from the institutional review board, and informed patient consent was waived. The 1.5-T DWI data of 42 patients with or without pancreatic disease, acquired by a respiratory-gated spin-echo echo-planar imaging sequence with 3 b values (0, 50, 800 s/mm²), were retrospectively analyzed. The IVIM-related parameters D', which is the apparent diffusion coefficient [ADC(50,800)], and f', as well as ADC(0,50), and conventional ADC(0,800) were calculated voxelwise. Regions of interest were analyzed in pancreatic adenocarcinomas (CAs, n = 12), neuroendocrine pancreatic tumors (NETs, n = 9), and chronic pancreatitis (CPs, n = 11), not affected tissue of each pathologic group, and in the head, body, and tail of the healthy pancreas (n = 10).

Results: By ADC(0,800) and D', CAs could hardly be distinguished from neuroendocrine pancreatic tumors and chronic pancreatitis. However, CAs revealed very low ADC(0,50) and f' values, which differed significantly from all other groups. In the healthy pancreas, ADC(0,800) and D' values were significantly higher for the head than for the body and tail, but no significant differences were found for ADC(0,50) and f'.

Conclusions: The determination of IVIM-based microcirculation-sensitive parameter maps from DWI with 3 b values significantly improved the discrimination of CAs from NETs, CPs, and the healthy tissue.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RLI.0b013e3182a71cc3DOI Listing

Publication Analysis

Top Keywords

diagnostic benefit
8
benefit intravoxel
8
intravoxel incoherent
8
incoherent motion
8
neuroendocrine pancreatic
8
pancreatic tumors
8
chronic pancreatitis
8
head body
8
body tail
8
healthy pancreas
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!