Noise reduction is often essential for cochlear implant (CI) recipients to achieve acceptable speech perception in noisy environments. Most noise reduction algorithms applied to audio signals are based on time-frequency representations of the input, such as the Fourier transform. Algorithms based on other representations may also be able to provide comparable or improved speech perception and listening quality improvements. In this paper, a noise reduction algorithm for CI sound processing is proposed based on the wavelet transform. The algorithm uses a dual-tree complex discrete wavelet transform followed by shrinkage of the wavelet coefficients based on a statistical estimation of the variance of the noise. The proposed noise reduction algorithm was evaluated by comparing its performance to those of many existing wavelet-based algorithms. The speech transmission index (STI) of the proposed algorithm is significantly better than other tested algorithms for the speech-weighted noise of different levels of signal to noise ratio. The effectiveness of the proposed system was clinically evaluated with CI recipients. A significant improvement in speech perception of 1.9 dB was found on average in speech weighted noise.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3784455PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0075662PLOS

Publication Analysis

Top Keywords

noise reduction
20
reduction algorithm
12
speech perception
12
noise
8
wavelet transform
8
reduction
5
algorithm
5
speech
5
wavelet-based noise
4
algorithm clinical
4

Similar Publications

DECT sparse reconstruction based on hybrid spectrum data generative diffusion model.

Comput Methods Programs Biomed

January 2025

Key Laboratory of Computer Network and Information Integration (Southeast University), Ministry of Education, Nanjing, China; School of Computer Science and Engineering, Southeast University, Nanjing, China.

Purpose: Dual-energy computed tomography (DECT) enables the differentiation of different materials. Additionally, DECT images consist of multiple scans of the same sample, revealing information similarity within the energy domain. To leverage this information similarity and address safety concerns related to excessive radiation exposure in DECT imaging, sparse view DECT imaging is proposed as a solution.

View Article and Find Full Text PDF

Developmental and molecular effects of pure-tone sine wave exposure on early zebrafish embryo development: Implications for reproductive health.

Ecotoxicol Environ Saf

January 2025

Key laboratory of Birth Defects and Related Disease of Women and Children (Sichuan University), Ministry of Education, Chengdu, Sichuan, China; SCU-CUHK Joint Laboratory for Reproductive Medicine, Zebrafish Research Platform, West China Second University Hospital, Children's Medicine Key Laboratory of Sichuan Province, Sichuan University/Key Laboratory of Birth Defects and Related Diseases of Women and Children (Sichuan University), Ministry of Education, Chengdu 610000, PR China. Electronic address:

Noise pollution has become a significant concern for human health, yet its effects on early embryonic development remain underexplored. Specifically, data on the impact of sine wave noise on newly fertilized embryos is limited. This study aimed to address this gap by using zebrafish embryos at the 1-cell stage as a model to assess the toxicity of sine waves, following OECD Test No.

View Article and Find Full Text PDF

Work-related temporary hearing loss and associated factors among textile industry workers in Amhara region, Ethiopia: a cross-sectional study.

BMJ Open

December 2024

Department of Environmental and Occupational Health and Safety, College of Medicine and Health Science, Institute of Public Health, University of Gondar, Gondar, Ethiopia.

Objectives: This study was designed to assess occupational noise exposure levels, prevalence of temporary hearing loss and associated factors among textile industry workers in Amhara region, Ethiopia.

Design: An institution-based, cross-sectional study was conducted between June and July 2022. Participants were selected via a simple random sampling technique.

View Article and Find Full Text PDF

While gas chromatography mass spectrometry (GC-MS) has long been used to identify compounds in complex mixtures, this process is often subjective and time-consuming and leaves a large fraction of seemingly good-quality spectra unidentified. In this work, we describe a set of new mass spectral library-based methods to assist compound identification in complex mixtures. These methods employ mass spectral uniqueness and compound ubiquity of library entries alongside noise reduction and automated comparison of retention indices to library compounds.

View Article and Find Full Text PDF

Optimizing hip MRI: enhancing image quality and elevating inter-observer consistency using deep learning-powered reconstruction.

BMC Med Imaging

January 2025

Department of Magnetic Resonance Imaging, The First Affiliated Hospital, Zhengzhou University, Zhengzhou, 450052, China.

Background: Conventional hip joint MRI scans necessitate lengthy scan durations, posing challenges for patient comfort and clinical efficiency. Previously, accelerated imaging techniques were constrained by a trade-off between noise and resolution. Leveraging deep learning-based reconstruction (DLR) holds the potential to mitigate scan time without compromising image quality.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!