Purpose: The aim of this study was to evaluate the positron emission tomography (PET) component of [(18)F]choline PET/MRI and compare it with the PET component of [(18)F]choline PET/CT in patients with histologically proven prostate cancer and suspected recurrent prostate cancer.

Methods: Thirty-six patients were examined with simultaneous [(18)F]choline PET/MRI following combined [(18)F]choline PET/CT. Fifty-eight PET-positive lesions in PET/CT and PET/MRI were evaluated by measuring the maximum and mean standardized uptake values (SUVmax and SUVmean) using volume of interest (VOI) analysis. A scoring system was applied to determine the quality of the PET images of both PET/CT and PET/MRI. Agreement between PET/CT and PET/MRI regarding SUVmax and SUVmean was tested using Pearson's product-moment correlation and Bland-Altman analysis.

Results: All PET-positive lesions that were visible on PET/CT were also detectable on PET/MRI. The quality of the PET images was comparable in both groups. Median SUVmax and SUVmean of all lesions were significantly lower in PET/MRI than in PET/CT (5.2 vs 6.1, p<0.05 and 2.0 vs 2.6, p<0.001, respectively). Pearson's product-moment correlation indicated highly significant correlations between SUVmax of PET/CT and PET/MRI (R=0.86, p<0.001) as well as between SUVmean of PET/CT and PET/MRI (R=0.81, p<0.001). Bland-Altman analysis revealed lower and upper limits of agreement of -2.77 to 3.64 between SUVmax of PET/CT vs PET/MRI and -1.12 to +2.23 between SUVmean of PET/CT vs PET/MRI.

Conclusion: PET image quality of PET/MRI was comparable to that of PET/CT. A highly significant correlation between SUVmax and SUVmean was found. Both SUVmax and SUVmean were significantly lower in [(18)F]choline PET/MRI than in [(18)F]choline PET/CT. Differences of SUVmax and SUVmean might be caused by different techniques of attenuation correction. Furthermore, differences in biodistribution and biokinetics of [(18)F]choline between the subsequent examinations and in the respective organ systems have to be taken into account.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00259-013-2560-2DOI Listing

Publication Analysis

Top Keywords

pet component
12
[18f]choline pet/mri
12
[18f]choline pet/ct
12
pet/ct pet/mri
12
suvmax suvmean
12
simultaneous [18f]choline
8
pet/mri
8
prostate cancer
8
pet/ct
8
component [18f]choline
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!