A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Percutaneous peritoneal dialysis catheter insertion by a nephrologist: a new, simple, and safe technique. | LitMetric

Percutaneous peritoneal dialysis catheter insertion by a nephrologist: a new, simple, and safe technique.

Perit Dial Int

Department of Internal Medicine, Nephrology Division, King Fahd University Hospital, Dammam University, Saudi Arabia.

Published: January 2015

Background: Insertion of the peritoneal dialysis (PD) catheter by a nephrologist has been encouraged by several studies. The ultimate goal is to provide safe, timely, and effective catheter insertion without an unduly long wait time or delay. The success of PD depends partly on the ease of catheter insertion. We developed a new technique for percutaneous PD catheter insertion by nephrologists. Our new technique, in addition to being easy, proved to be safe and to eliminate the need for the peel-away sheath.

Methods: Data were collected prospectively on all patients having a PD catheter inserted by a nephrologist using our new technique (40 catheters in 38 patients). All catheters were evaluated for infectious and mechanical complications.

Results: The mean duration of the procedure from skin sterilization to the end of insertion was 24 ± 3 minutes. No bowel perforation or serious hemorrhage was recorded. Poor initial drainage was recorded in 12.5% of the catheters (n = 5) during the 4 weeks after insertion. The incidence of early exit-site leakage was 2.5% (1 catheter). Episodes of exit-site infection occurred in 5.0% and 12.5% of catheters (within 1 month and by the end of study period respectively). Two episodes of peritonitis were reported by the end of the 12-month period. Catheter survival was 95.0% and 87.5% at 6 months and 12 months respectively.

Conclusions: Percutaneous bedside placement of PD catheters using our new technique is safe and carries less morbidity in terms of bowel perforation, catheter-related infection, and exit-site leak. In addition, our new technique appears to have a high success rate and to offer considerable savings in terms of operating time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3968106PMC
http://dx.doi.org/10.3747/pdi.2012.00160DOI Listing

Publication Analysis

Top Keywords

catheter insertion
16
peritoneal dialysis
8
catheter
8
dialysis catheter
8
bowel perforation
8
125% catheters
8
insertion
7
technique
6
catheters
5
percutaneous peritoneal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!