A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Application of X-ray grating interferometry for the imaging of joint structures. | LitMetric

Application of X-ray grating interferometry for the imaging of joint structures.

Anat Sci Int

Department of Anatomy, Faculty of Medicine, Saitama Medical University, Moro-Hongo 38, Moroyama, Saitama, 350-0495, Japan,

Published: March 2014

Conventional X-ray absorption contrast imaging does not depict soft tissues, such as cartilage, in sufficient detail. For visualization of the soft tissues, X-ray phase-contrast imaging is more sensitive than absorption-contrast imaging. The basic concept of the X-ray phase-contrast imaging used in this study is similar to that of differential interference contrast (Nomarski) microscopy. We applied Talbot-Lau X-ray interferometry to visualize the joint structures in the right hand and knee of a donated cadaver. This imaging system simultaneously produced three different types of images: an absorption image, a differential phase image, and a visibility image. The interface between the articular cartilage of the metacarpo-phalangeal joint and fluid or the bony cortex was clearly demonstrated on the differential phase image, whereas this interface was unclear on the absorption image. Within the knee joint, the surface of the articular cartilage was demonstrated both on the differential phase and visibility images; the medial collateral ligament and medial meniscus were also visualized successfully. These results are clinically significant for the diagnosis and therapeutic estimation of rheumatoid arthritis and related joint diseases. This feasibility study on the clinical application of this imaging tool was a collaborative effort of researchers in the fields of physics, radiology, and gross anatomy.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12565-013-0204-zDOI Listing

Publication Analysis

Top Keywords

differential phase
12
joint structures
8
soft tissues
8
x-ray phase-contrast
8
phase-contrast imaging
8
absorption image
8
phase image
8
image interface
8
articular cartilage
8
demonstrated differential
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!