An optical technique is proposed for the accurate calibration of pulsed high magnetic fields utilizing the magnetic field dependent photoluminescence (PL) properties in an Er(3+):YVO(4) single crystal at 80 K. Bright green PL emissions are excited by a 487.5 nm laser line and can be enhanced greatly by a magnetic field at certain field values (B(c)). Since the B(c)'s under 10 T are extremely stable for a given sample at a certain temperature, and the FWHM of the enhancement peaks are less than 0.9 T, an Er(3+):YVO(4) single crystal is proven to be a good candidate for pulsed high magnetic field calibration. The detailed processes and numerous advantages of the technique are presented in this work.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.38.003754DOI Listing

Publication Analysis

Top Keywords

magnetic field
20
er3+yvo4 single
12
single crystal
12
high magnetic
12
field calibration
8
pulsed high
8
magnetic
6
field
5
field induced
4
induced great
4

Similar Publications

Magnetic nanoparticles of Nd2Fe14B prepared by ethanol-assisted wet ball milling technique.

Sci Rep

January 2025

Environmental and Occupational Hazards Control Research Center, Research Institute for Health Sciences and Environment, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

The magnetic material Nd2Fe14B is one of the strongest magnetic materials found in nature. The demand for the production of these nanoparticles is significantly high due to their exceptional properties. The aim of the present study is to synthesize magnetic nanoparticles of Nd2Fe14B using ethanol in the wet ball milling technique (WBMT).

View Article and Find Full Text PDF

Carbon-supported Fe single atom nanozymes with long-lasting ROS generation and high NIR photothermal performance for synergistic cancer therapy.

J Colloid Interface Sci

April 2025

High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Science, Hefei, Anhui 230031, PR China; University of Science and Technology of China, Hefei, Anhui 230026, PR China. Electronic address:

Synergistic therapy combining photothermal therapy (PTT) and chemodynamic therapy (CDT) has proven to be a highly effective strategy for cancer treatment. However, PTT heavily relies on the accumulation of therapeutic agents at the tumor site. The peroxidase (POD) activity of common catalysts can be rapidly exhausted during the accumulation process, prior to laser intervention, thereby diminishing the synergistic enhancement effect of the combined therapy.

View Article and Find Full Text PDF

The electrical conductivity and antibacterial properties are crucial characteristics for bacterial cellulose (BC) based membranes to be broadly applied in the field of wearable electronics. In the study, to achieve these aims, alpha-lipoic acid (LA) was utilized as anchoring groups and reducing agent, hydroxypropyl-β-cyclodextrin (HP-β-CD) capped magnetic particles (FeO NPs) and the in-situ formed silver nanoparticles (AgNPs) were sequentially incorporated into the BC matrix to fabricate BC based nanocomposite membranes (HP-β-CD/FeO/LA@BC and HP-β-CD/FeO/LA/Ag@BC). Fourier transform attenuated total reflectance infrared spectroscopy (FTIR-ATR) and field emission scanning electron microscopy (FE-SEM) analysis proved the dense networks were formed in the modified BC membranes.

View Article and Find Full Text PDF

Purpose: To improve the current method for MRI turbulence quantification which is the intravoxel phase dispersion (IVPD) method. Turbulence is commonly characterized by the Reynolds stress tensor (RST) which describes the velocity covariance matrix. A major source for systematic errors in MRI is the sequence's sensitivity to the variance of the derivatives of velocity, such as the acceleration variance, which can lead to a substantial measurement bias.

View Article and Find Full Text PDF

Overactive bladder (OAB) is a prevalent chronic condition affecting approximately 12% of adults, with incidence increasing with age. While pharmacological and behavioural therapies are standard treatments, their efficacy is often limited by side effects and poor adherence. This study aimed to compare the therapeutic effects of precision magnetic stimulation guided by motor-evoked potential with general magnetic therapy in patients with OAB.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!