Visceral stent patency in fenestrated stent grafting for abdominal aortic aneurysm repair.

J Vasc Surg

Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands. Electronic address:

Published: February 2014

AI Article Synopsis

  • The study examines the effectiveness of fenestrated endovascular abdominal aortic aneurysm repair (F-EVAR) in treating aneurysms near visceral arteries, finding high rates of vessel patency.
  • Over a decade, 138 patients were treated, receiving a mix of scallops and fenestrations for their target vessels, leading to a technical success rate of 98%.
  • At one year post-procedure, the overall stent patency was 95.7%, with renal artery stents performing slightly better at 97.4%, showing no significant differences between covered and uncovered stents.

Article Abstract

Objective: Fenestrated endovascular abdominal aortic aneurysm repair (F-EVAR) has been introduced for treatment of aneurysms in which visceral arteries are incorporated. Patency of target vessels has been reported to be excellent. Results of the use of stent grafts to accommodate visceral arteries in F-EVAR are presented in this study, including an overview of factors that affect outcome.

Methods: All patients treated with fenestrated stent grafts in a single center between November 2001 and October 2011 were reviewed. Patients treated for suprarenal, juxtarenal, and infrarenal short-necked aortic aneurysms were included. Patients with thoraco-abdominal aneurysms or aneurysms treated with grafts with fixed side branches were excluded. Polytetrafluoroethylene covered stents were used routinely since June 2005. Target vessels and stents were examined using computed tomography angiography reconstructions. Primary end points were primary patency, defined as the absence of occlusion, and loss of renal function. Secondary end points were technical success, stenosis (defined as a ≥50% angiographic diameter reduction), stent fracture, and mortality.

Results: A total of 138 patients with a median age of 73 years (range, 50-91 years) met the inclusion criteria. Median computed tomography angiography follow-up was 13 months (range, 1-97 months). In total, 392 target vessels were provided with 140 scallops and 252 fenestrations. Visceral stents (-grafts) were placed in 254 target vessels. Technical success was obtained in 249 arteries (98.0%). Overall stent patency of target vessels was 95.7% at 1 year and 88.6% at 4 years. Renal artery stent patency was 97.4% at 1 year and 91.2% at 4 years (96.8% and 89.1% for uncovered stents; 97.3% and 92.4% for covered stents, respectively). There was no significant difference in patency between covered and uncovered stents in renal arteries (P = .71). Renal artery stenosis occurred in 26 stented arteries (11.3%) and occlusion in seven arteries. Renal artery stent stenosis occurred significantly more in uncovered than in covered stents (P = .04). Stent fractures occurred more in uncovered than in covered stents (P = .01) and was associated with a significantly lower visceral stent patency rate (P < .01). During follow-up, 13 patients developed permanent renal function impairment (9.4%), of which two required permanent dialysis (1.4%). Renal dysfunction was significantly associated with renal stent occlusion or stenosis (P < .01).

Conclusions: Patency rates of visceral artery stent (-grafts) in F-EVAR were 95.7% at 1 year and 88.6% at 4 years. Patency rates were affected by stent fractures, which occurred more in uncovered compared with covered stents. Renal artery stent stenosis occurred more in uncovered compared with covered stents. Renal dysfunction was significantly associated with renal stent occlusion or stenosis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvs.2013.08.005DOI Listing

Publication Analysis

Top Keywords

covered stents
24
target vessels
20
stent patency
16
renal artery
16
artery stent
16
occurred uncovered
16
stent
14
stents renal
12
stenosis occurred
12
renal
11

Similar Publications

Objective: The aim of this study was to perform a comparative pre-clinical evaluation of a new fenestrated endovascular aneurysm repair dedicated stent using perfused 3D printed patient anatomies.

Methods: The test setup included a pulsatile pump set to reproduce human haemodynamics, four 3D printed pararenal aneurysms connected to a bench test, and four corresponding fenestrated grafts (Zenith Fenestrated; Cook, Bloomington, IN, USA). Bridging stents were sized based on analysis of patients computed tomography scans and included either four standard covered stents (BeGraft [BG]; Bentley, Hechingen, Germany) or four similar covered stent grafts mounted on a modified balloon to allow stent implantation and flaring in one step (BeFlared [BF]; Bentley).

View Article and Find Full Text PDF

Background: Due to the heterogeneity of literature findings, stent type selection for the endovascular treatment of complex aorto-iliac occlusive disease remains challenging. The BELSTREAM study, a physician-initiated, prospective, multicenter, single-arm study, aims to report the safety and efficacy of the balloon expandable LifeStream Peripheral Stent Graft System (BD, Tempe, Arizona, USA) for the treatment of complex TASC C and D aorto-iliac artery lesions.

Methods: Seventy patients and 133 lesions were included at six Belgian institutions.

View Article and Find Full Text PDF

Gastrointestinal bleeding after pancreatoduodenectomy: Report of four cases.

World J Gastrointest Surg

January 2025

Department of Gastroenterology and Hepatology, Xuanwu Hospital, Capital Medical University, Beijing 100053, China.

Background: Postpancreatectomy hemorrhage is one of the most severe and life-threatening complications after pancreaticoduodenectomy. We present four cases of gastrointestinal bleeding patients to clarify its appropriate treatment and prevention.

Case Summary: The main symptoms included black stool, hematochezia, haematemesis, blood in the nasogastric tube, and hemorrhagic shock.

View Article and Find Full Text PDF

Background And Aim: Although long self-expandable metal stent (SEMS) with a sufficient intragastric portion is typically preferred for endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS), this design can complicate endoscopic re-intervention for recurrent biliary obstruction (RBO). We evaluated the efficacy and safety of endoscopic re-intervention for RBO through the stent after EUS-HGS using a novel partially covered SEMS with an anchoring flange.

Methods: The partially covered SEMS was designed with a intrahepatic uncovered portion measuring 1.

View Article and Find Full Text PDF

Background And Aim: Managing benign biliary stricture endoscopically is complicated and challenging. This study aimed to evaluate the safety and efficacy of a 6-month placement of a fully covered self-expanding metallic stent for refractory benign biliary stricture.

Methods: Twenty-two patients with refractory benign biliary stricture (13 with chronic pancreatitis and 9 without) were recruited from five higher tertiary care centers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!