The electrocardiographic (ECG) findings in patients with pulmonary embolism (PE) and no previous cardiopulmonary disease are well documented; however, investigation of the relation of ECG abnormalities to right ventricular (RV) enlargement has been limited. The purpose of the present investigation was to assess further the relation of ECG changes in acute PE to RV cavity enlargement (dilation). The records of patients hospitalized from January 2009 to December 2012 with acute PE and no previous cardiopulmonary disease were reviewed. A total of 289 patients were included. RV cavity enlargement was present in 141 patients (49%). Normal ECG findings were less prevalent in patients with PE and RV enlargement than those with PE and no RV enlargement (35 of 141 [25%] vs 56 of 148 [38%]; p = 0.02). One or more of the traditional ECG manifestations of acute cor pulmonale (S1Q3T3, complete right bundle branch block, P pulmonale, or right axis deviation) was found in 18 of 141 patients (13%) with RV enlargement and 13 of 148 (8.8%) with a normal size RV (p = NS). None of the ECG abnormalities was sensitive for RV enlargement. The specificity of P and QRS abnormalities was high. The positive predictive values were ≤83% or had wide 95% confidence intervals. The negative predictive values ranged from 50% to 61%. In conclusion, ECG findings were not useful for the detection or exclusion of RV cavity enlargement in patients with acute PE.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2013.08.030DOI Listing

Publication Analysis

Top Keywords

ecg findings
12
cavity enlargement
12
enlargement
9
pulmonary embolism
8
ventricular enlargement
8
previous cardiopulmonary
8
cardiopulmonary disease
8
relation ecg
8
ecg abnormalities
8
enlargement 141
8

Similar Publications

A Nomogram utilizing ECG P-wave parameters to predict recurrence risk following catheter ablation in paroxysmal atrial fibrillation.

J Cardiothorac Surg

January 2025

Department of Cardiology, Fujian Medical University Union Hospital, Fujian Heart Medical Center, Fujian Institute of Coronary Heart Disease, Fujian Clinical Medical Research Center for Heart and Macrovascular Disease, Fuzhou, 350001, China.

Objective: The objective of this study is to assess the predictive utility of perioperative P-wave parameters in patients with paroxysmal atrial fibrillation (PAF) undergoing catheter ablation, and to develop a predictive model using these parameters.

Methods: A total of 213 patients with PAF undergoing catheter ablation were retrospectively analyzed. P-wave parameters were measured within 3 days preoperatively and on the day postoperatively to determine their predictive significance for postoperative PAF recurrence.

View Article and Find Full Text PDF

Premature Coronary Artery Disease Presenting as STEMI in a Teenager.

J Investig Med High Impact Case Rep

January 2025

LSU Health Shreveport, LA, USA.

An 18-year-old teenager with significant atherosclerotic cardiovascular disease (ASCVD) risk factors developed acute chest pain. His electrocardiogram showed inferior ST-segment elevations. Emergent coronary angiogram revealed complete thrombotic occlusion of the right coronary artery.

View Article and Find Full Text PDF

A Deep Learning Approach for Mental Fatigue State Assessment.

Sensors (Basel)

January 2025

Institute of Artificial Intelligence in Sports, Capital University of Physical Education and Sports, Beijing 100191, China.

This study investigates mental fatigue in sports activities by leveraging deep learning techniques, deviating from the conventional use of heart rate variability (HRV) feature analysis found in previous research. The study utilizes a hybrid deep neural network model, which integrates Residual Networks (ResNet) and Bidirectional Long Short-Term Memory (Bi-LSTM) for feature extraction, and a transformer for feature fusion. The model achieves an impressive accuracy of 95.

View Article and Find Full Text PDF

Generally, the electrocardiography (ECG) system plays an important role in preventing and diagnosing heart diseases. To further improve the amenity and convenience of using an ECG system, we built a customized capacitive electrocardiography (cECG) system with one wet electrode, sixteen non-contact electrodes, two ADS1299 chips, and one STM32F303-based microcontroller unit (MCU). This new cECG system could acquire, save, and display the ECG data in real time.

View Article and Find Full Text PDF

Stuck prosthetic valves, often resulting from pannus formation or thrombus accumulation, represent a critical complication in prosthetic valve management, carrying significant risks for morbidity and mortality. This study aims to identify factors associated with stuck valve development and assess the effectiveness of interventions in restoring normal valve function. A total of 27 patients with stuck valves were analyzed, including mitral, aortic, and tricuspid valve cases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!