Background: To investigate the interfraction displacement and volume variation of primary thoracic esophagus carcinoma with enhanced four-dimensional computed tomography (4DCT) scanning during fractionated radiotherapy.

Methods: 4DCT data sets were acquired at the time of treatment simulation and every ten fraction for each of 32 patients throughout treatment. Scans were registered to baseline (simulation) 4DCT scans by using bony landmarks. The gross tumor volumes (GTVs) were delineated on each data set. Coordinates of the GTV centroids were acquired on each respiration phase. Distance between center of the GTV contour on the simulation scan and the centers on subsequent scans were used to assess interfraction displacement between fractions. Volumes were constructed using three approaches: The GTV delineated from the maximum intensity projection (MIP) was defined IGTVMIP, all 10 GTVs were combined to form IGTV10, GTVmean was the average of all 10 phases of each GTV.

Results: Interfraction displacement in left-right (LR), anterior-posterior (AP), superior-inferior (SI) directions and 3D vector were 0.13 ± 0.09 cm, 0.16 ± 0.12 cm, 0.34 ± 0.26 cm and 0.43 ± 0.24 cm, respectively between the tenth fraction and simulation 4DCT scan. 0.14 ± 0.09 cm, 0.19 ± 0.16 cm, 0.45 ± 0.43 cm and 0.56 ± 0.40 cm in LR, AP, SI and 3D vector respectively between the twentieth fraction and simulation 4DCT scan. Displacement in SI direction was larger than LR and AP directions during treatment. For distal esophageal cancer, increased interfraction displacements were observed in SI direction and 3D vector (P = 0.002 and P = 0.001, respectively) during radiotherapy. The volume of GTVmean, IGTVMIP, and IGTV10 decreased significantly at the twentieth fraction for middle (median: 34.01%, 33.09% and 28.71%, respectively) and distal (median: 22.76%, 25.27% and 23.96%, respectively) esophageal cancer, but for the upper third, no significant variation were observed during radiotherapy.

Conclusions: Interfractional displacements in SI direction were larger than LR and AP directions. For distal location, significant changes were observed in SI direction and 3D vector during radiotherapy. For middle and distal locations, the best time to reset position should be selected at the twentieth fraction when the primary tumor target volume changed significantly, and it was preferable to guide target correction and planning modification.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4016114PMC
http://dx.doi.org/10.1186/1748-717X-8-224DOI Listing

Publication Analysis

Top Keywords

interfraction displacement
16
esophageal cancer
12
simulation 4dct
12
twentieth fraction
12
displacement volume
8
primary thoracic
8
fraction simulation
8
4dct scan
8
direction larger
8
larger directions
8

Similar Publications

Purpose: The purpose of this study was to quantify the intra- and interfraction motion of the target volume and organs at risk (OARs) during adaptive radiotherapy (ART) for uterine cervical cancer (UCC) using MR-Linac and to identify appropriate UCC target volume margins for adapt-to-shape (ATS) and adapt-to-position (ATP) workflows. Then, the dosimetric differences caused by motion were analyzed.

Methods: Thirty-two UCC patients were included.

View Article and Find Full Text PDF

Introduction: Non-invasive frameless systems have paved its way for stereotactic radiotherapy treatments compared to gold standard invasive rigid frame-based systems as they are comfortable to patients, do not have risk of pain, bleeding, infection, frame slippage and have similar treatment efficacy.

Aim And Objective: To estimate immobilisation accuracy (interfraction and intrafraction) and PTV margins with double shell positioning system (DSPS) using daily image guidance for stereotactic radiotherapy in patients with brain tumors.

Materials And Method: A prospective study was done in 19 cranial tumor patients with KPS ≥70, immobilized by the DSPS with mouth bite and treated with LINAC based image guided stereotactic radiotherapy.

View Article and Find Full Text PDF

Introduction: Consensus contouring guidelines for intensity-modulated-radiation-therapy (IMRT) of patients with locally advanced cervix cancer (LACC) advise including the whole uterus in the target volume and adding generous planning-target-volumes (PTVs) to account for motion uncertainties of the gross-tumor-volume (GTV). The primary objective of this analysis was to assess the interfractional GTV motions using a magnetic-resonance-image (MRI) guided-Radiation-Therapy (MRgRT) system to investigate the margins required for MRgRT treatments.

Methods: 125 daily set-up MRIs from five patients with LACC who received MRgRT were analyzed.

View Article and Find Full Text PDF

Introduction: The inter-fraction motion of pelvic ± para-aortic (PA) nodal volumes in prostate cancer patients with involved nodes is yet to be quantified and the optimal IGRT strategy for these patients is currently unknown.

Methods: A single-centre retrospective evaluation was performed investigating inter-fraction motion in the prostate and involved nodal volumes of patients receiving pelvic ± PA nodal irradiation. Patients were selected for inclusion if they; were undergoing prostate + pelvic node +/- PA node radiation for prostate cancer with involved lymph nodes and had received daily online CBCT scans.

View Article and Find Full Text PDF

Liver respiratory-induced motion estimation using abdominal surface displacement as a surrogate: robotic phantom and clinical validation with varied correspondence models.

Int J Comput Assist Radiol Surg

August 2024

Robotics and Mechatronics, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, 7500 AE, Enschede, Netherlands.

Article Synopsis
  • The study investigates the use of RGB-D cameras to estimate liver movement caused by breathing, aiming to validate their effectiveness in human subjects while comparing different models for accuracy.
  • Two experiments were conducted: one with a robotic liver phantom and another with human subjects, testing various correspondence models to improve motion estimation.
  • Results showed that the RGB-D cameras could accurately estimate liver motion with minimal error (under 5 mm), highlighting their potential for non-invasive medical imaging applications.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!