Application of sweat patch screening for 16 drugs and metabolites using a fast and highly selective LC-MS/MS method.

Ther Drug Monit

*Laboratory for Clinical and Forensic Toxicology and Drugs Analysis, Department of Hospital and Clinical Pharmacy, University of Groningen, University Medical Center Groningen, The Netherlands; †SumID-Project, Zorgontwikkeling, Tactus Addiction Medicine, Deventer, The Netherlands; and ‡ACSW-Nijmegen Institute for Scientist-Practitioners in Addiction, Radboud University, Nijmegen, The Netherlands.

Published: February 2014

Background: To facilitate the monitoring of drug abuse by patients, a method was developed and validated for fast and highly selective screening for amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine, methylenedioxyamphetamine, methylenedioxyethylamphetamine, methylphenidate, cocaine, benzoylecgonine, morphine, codeine, heroin, 6-monoacteylmorphine, methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine, nicotine, and cotinine in PharmCheck sweat patches. The analysis of sweat patches would provide a noninvasive alternative matrix to urine or blood samples.

Methods: The sweat patches were extracted during vigorous shaking for 10 minutes with 1.5 mL of 20 mmol/L ammonium formate, pH 7, and methanol (50%:50% vol/vol). The extracts were cleaned up by filtering through Whatman mini-Uniprep syringeless filter vials before injection. The method uses a single injection to detect and confirm all 16 drugs and metabolites within 9.6 minutes.

Results: The validated substances have a linear range of 3.0-300 nanograms per patch, except for nicotine which has a linear range of 30-3750 nanograms per patch. Stabilities of all substances in worn sweat patches were validated at room temperature for 7 days and as a processed sample in the autosampler at 10°C for 5 days. Only heroin was unstable, with high individual variability and reported bias and coefficient of variation of, respectively, -30.6% and 22.1% in worn sweat patches at room temperature. The monitoring of ion ratios was added to the validation criteria. This resulted in analytical cutoff concentrations of 3.0 and 60 nanograms per patch for nicotine with validated qualifier/quantifier ratios. All analytical cutoff concentrations were lower than the cutoff concentrations proposed by the Substance Abuse and Mental Health Services Administration.

Conclusions: The method uses validated cutoff concentrations, qualifier/quantifier ratios, and a simple extraction without extensive sample treatment for the analysis of 16 drugs and metabolites with a runtime of 9.6 minutes. This method was successfully applied for the analysis of 96 worn sweat patches to monitor patients for drug abuse. The results provided the physician or health-care professional with information about drug abuse and could be used to improve patient care with patient-specific therapy.

Download full-text PDF

Source
http://dx.doi.org/10.1097/FTD.0b013e3182a04febDOI Listing

Publication Analysis

Top Keywords

sweat patches
24
cutoff concentrations
16
drugs metabolites
12
drug abuse
12
nanograms patch
12
worn sweat
12
fast highly
8
highly selective
8
linear range
8
patch nicotine
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!