Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
We fabricated three piezoelectric components (PZT) that can produce ultrasonic waves with various generated power in order to improve the delivery of DNA molecule and polymer/DNA complexes into cells. Two cationic polymers (PEI and PDMAEMA) were interacted with DNA to form nano-scaled DNA/polymer complexes with/without the help of PZT devices. The application of PZT devices under optimal conditions helped to avoid cytotoxicity and greatly increased the transfection (DNA delivery) efficiency of these complexes in mammalian cells. The cytotoxicity and transfection efficiency were found to be correlated with the PZT-generated power, waveforms and duration of ultrasonic treatment. There was no observable cytotoxicity in our experimental models and, a maximum transfection efficiency 700% greater than that of polymer/DNA complexes without applying ultrasound was achieved. The transfection efficiency of plain polymer/DNA complexes (without PZT treatment) corresponded to a 630-fold increase in comparison to the naked DNA. The waveforms of generated ultrasound greatly influenced the transfection efficiency, while cytotoxicity was not significantly affected. This means that, for optimal DNA delivery, duration of the peak voltage (Vmax/Div) also plays a role. In addition, the generated waves from PZT do not cause dissociation of polymer/DNA complexes or a change in the particle sizes of these complexes. In conclusion, these results suggest that the operation of PZT devices can be a tunable/safe way to greatly improve DNA delivery for gene therapy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ultsonch.2013.08.019 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!