Task-evoked changes in cerebral oxygen metabolism can be measured using calibrated functional Magnetic Resonance Imaging (fMRI). This technique requires the use of breathing manipulations such as hypercapnia, hyperoxia or a combination of both to determine a calibration factor M. The M-value is usually obtained by extrapolating the BOLD signal measured during the gas manipulation to its upper theoretical physiological limit using a biophysical model. However, a recently introduced technique uses a combination of increased inspired concentrations of O2 and CO2 to saturate the BOLD signal completely. In this study, we used this BOLD saturation technique to measure M directly at 7Tesla (T). Simultaneous carbogen-7 (7% CO2 in 93% O2) inhalation and visuo-motor task performance were used to elevate venous oxygen saturation in visual and motor areas close to their maximum, and the BOLD signal measured during this manipulation was used as an estimate of M. As accurate estimation of M is crucial for estimation of valid oxidative metabolism values, these directly estimated M-values were assessed and compared with M-values obtained via extrapolation modelling using the generalized calibration model (GCM) on the same dataset. Average M-values measured using both methods were 10.4±3.9% (modelled) and 7.5±2.2% (direct) for a visual-related ROI, and 11.3±5.2% (modelled) and 8.1±2.6% (direct) for a motor-related ROI. Results from this study suggest that, for the CO2 concentration used here, modelling is necessary for the accurate estimation of the M parameter. Neither gas inhalation alone, nor gas inhalation combined with a visuo-motor task, was sufficient to completely saturate venous blood in most subjects. Calibrated fMRI studies should therefore rely on existing models for gas inhalation-based calibration of the BOLD signal.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.neuroimage.2013.09.035 | DOI Listing |
Background: Tau protein accumulation is closely linked to synaptic and neuronal loss in Alzheimer's disease (AD), resulting in progressive cognitive decline. Although tau-PET imaging is a direct biomarker of tau pathology, it is costly, carries radiation risks, and is not widely accessible. Resting-state functional MRI (rs-fMRI) complexity-an entropy-based measure of BOLD signal variation-has been proposed as a non-invasive surrogate biomarker of early neuronal dysfunction associated with tau pathology.
View Article and Find Full Text PDFJ Cereb Blood Flow Metab
January 2025
Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.
Hyperpolarized-C magnetic resonance imaging (HP-C MRI) was used to image changes in C-lactate signal during a visual stimulus condition in comparison to an eyes-closed control condition. Whole-brain C-pyruvate, C-lactate and C-bicarbonate production was imaged in healthy volunteers (N = 6, ages 24-33) for the two conditions using two separate hyperpolarized C-pyruvate injections. BOLD-fMRI scans were used to delineate regions of functional activation.
View Article and Find Full Text PDFPLoS One
January 2025
Centre for Neuroscience Studies, Queen's University, Kingston, Ontario, Canada.
Altered neural signaling in fibromyalgia syndrome (FM) was investigated with functional magnetic resonance imaging (fMRI). We employed a novel fMRI network analysis method, Structural and Physiological Modeling (SAPM), which provides more detailed information than previous methods. The study involved brain fMRI data from participants with FM (N = 22) and a control group (HC, N = 18), acquired during a noxious stimulation paradigm.
View Article and Find Full Text PDFHum Brain Mapp
February 2025
Computational Imaging Research Lab, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
Irregular and unpredictable fetal movement is the most common cause of artifacts in in utero functional magnetic resonance imaging (fMRI), affecting analysis and limiting our understanding of early functional brain development. The accurate detection of corrupted functional connectivity (FC) resulting from motion artifacts or preprocessing, instead of neural activity, is a prerequisite for reliable and valid analysis of FC and early brain development. Approaches to address this problem in adult data are of limited utility in fetal fMRI.
View Article and Find Full Text PDFJ Cereb Blood Flow Metab
January 2025
A. I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland.
Zero echo time (zero-TE) pulse sequences provide a quiet and artifact-free alternative to conventional functional magnetic resonance imaging (fMRI) pulse sequences. The fast readouts (<1 ms) utilized in zero-TE fMRI produce an image contrast with negligible contributions from blood oxygenation level-dependent (BOLD) mechanisms, yet the zero-TE contrast is highly sensitive to brain function. However, the precise relationship between the zero-TE contrast and neuronal activity has not been determined.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!