A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Structure effect on graphene-modified enzyme electrode glucose sensors. | LitMetric

Structure effect on graphene-modified enzyme electrode glucose sensors.

Biosens Bioelectron

State Key Laboratory for Advanced Metals and Materials, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, PR China.

Published: February 2014

Using structural characterizations and electrochemical measurements, we explored and investigated the effect of the structure of enzyme electrodes with glucose oxidase (GOD) that were modified by reduced graphene oxide (rGO) sheets. The rGO sheets with different defect density, layers, and oxygen concentrations were chosen to modify the enzyme electrode, and all the modified enzyme electrodes exhibited excellent electrocatalytic activities and performances towards glucose. The abundant defects in rGO induce easy absorption of GOD. At a low oxygen concentration, rGO sheets help to induce the direct electron transfer (DET) on the rGO-modified electrode, and at a higher oxygen concentration, the reduction of H2O2 occurred instead of DET on the surface of the rGO-modified electrode. When rGO modified the enzyme electrode under the working model of H2O2 reduction, an increase in the number of the oxygen functional groups could lead to an increase in the absorption of GOD, resulting in the improvement of the affinity and sensitivity of the biosensor. The rGO-modified enzyme electrode can provide faster response, higher sensitivity, and better affinity by optimizing and controlling the structure of graphene and its derivatives.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2013.07.022DOI Listing

Publication Analysis

Top Keywords

enzyme electrode
16
rgo sheets
12
enzyme electrodes
8
modified enzyme
8
absorption god
8
oxygen concentration
8
rgo-modified electrode
8
enzyme
6
electrode
6
rgo
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!