Background: Accurate evaluation of aortic root geometry is necessary in congenital aortic valve lesions in children, to guide surgical or angiographical intervention.

Aim: To compare aortic annulus diameters measured by two- and three-dimensional transthoracic echocardiography (2D- and 3D-TTE), to determine the feasibility and reproducibility of 3D imaging and assess the dynamic changes during the cardiac cycle.

Methods: Thirty children without heart disease were prospectively included. Two orthogonal aortic annulus diameters were measured offline using multiplanar reconstruction in diastole and in systole and were compared with the measurement of the aortic annulus diameter by 2D-TTE.

Results: Mean age was 11±3.6 years. Feasibility of 3D imaging was 100%. The coefficients of intra- and interobserver variability were 3.5% and 6%, respectively. The 2D mean diameter was significantly smaller than the 3D maximum diameter in systole (1.94 vs. 2.01mm; p=0.005). 2D and 3D measurements were well correlated (p<0.0001). The maximum and minimum diameters in 3D were significantly different both in systole and in diastole (p<0.001) underlining an aortic annulus eccentricity. The mean aortic annulus diameters were not significantly different between systole and diastole, with important individual variability during the cardiac cycle.

Conclusion: This study demonstrated the feasibility and reproducibility of 3D-TTE for the assessment of the aortic annulus diameter in a normal paediatric population. Because of an underestimation of the maximum diameter by 2D-TTE and the asymmetry of the aortic annulus, 3D measurements could be important before percutaneous aortic valvuloplasty or surgical replacement.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acvd.2013.06.049DOI Listing

Publication Analysis

Top Keywords

aortic annulus
16
two- three-dimensional
8
three-dimensional transthoracic
8
transthoracic echocardiography
8
measurement aortic
8
annulus diameter
8
annulus diameters
8
diameters measured
8
aortic
6
comparison two-
4

Similar Publications

Severe mitral regurgitation (MR) following surgical repair of the mitral valve poses a significant clinical challenge. Patients who have undergone surgery are typically at high risk for a second operation. This report details the case of a 54-year-old male who underwent aortic valve replacement and mitral valve repair using a 34-ring, 14 years prior.

View Article and Find Full Text PDF

The Y-incision aortic annular enlargement (AAE) has been established as a safe and effective technique for upsizing the aortic annulus by 3 to 4 valve sizes. However, concerns have been raised regarding its technical complexity during reoperations, particularly given the extensive enlargement of the aortic annulus and root. We present a case of reoperative aortic valve replacement after previous Y-incision AAE for prosthetic valve endocarditis and aortic root abscess.

View Article and Find Full Text PDF

Among repairs for ventriculoarterial discordance, ventricular septal defect, and pulmonary stenosis, aortic root translocation (Nikaidoh operation) offers the most anatomic result. With a diminutive pulmonary annulus or hypoplastic left ventricular outflow tract, the distance gained posteriorly with aortic translocation is negligible. We developed the "hemi-Nikaidoh" procedure as an alternative.

View Article and Find Full Text PDF

Background: Partial heart transplantation (PHT) is a novel procedure for children in need of a growing valve replacement option. One challenge is identifying suitable donor valves. Semilunar heart valves from patients receiving a retransplant may be a source, however their functionality and growth potential especially at the time of retransplant are unknown.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!