Aims: The objective of this study was to correlate the electrocardiogram (ECG) modification during an Ajmaline challenge in patients affected by the Brugada syndrome and implanted with an implantable cardioverter-defibrillator (ICD) with the morphological changes of their ICD's intracardiac electrogram (IEGM).

Methods And Results: Sixteen type 1 Brugada syndrome patients implanted with a St Jude Medical AnalyST(®) ICD were enrolled and underwent ajmaline challenge. Intracardiac electrograms and 12 lead ECG signals were collected over the duration of the study and analysed off-line. The right precordial ECG leads were in both the third and fourth intercostal space by putting V5 and V6 in V1 and V2 at the third intercostal space. Two patients were excluded from the analysis due to signal noise issues. Of the remaining 14 patients, 12 and 2 patients were adjudicated to have positive and negative ajmaline challenges, respectively, based on standard ECG criteria. In the ajmaline positive patients, the IEGM T wave amplitude changes were more prominent than those of the IEGM ST segment (-898 ± 463 vs. -55 ± 381 µV, P < 0.05). Furthermore, all of these T wave amplitude changes were in the negative polarity, whereas the change in polarity of the ST segment was mixed. The changes in the IEGM T wave amplitude and ST segment were significantly smaller in the ajmaline negative patients compared with those in the ajmaline positive patients [211 ± 158 (P < 0.05) and 107 ± 54 (P < 0.05) µV, respectively). Over all 14 analysable patients, the change in the ECG ST segment over the timecourse of the ajmaline challenge correlated better with the IEGM T wave amplitude change (R = 0.72 ± 0.33) than the IEGM ST segment change (R = 0.63 ± 0.33). Applying an IEGM T wave amplitude change cut-off of 400 µV for predicting the outcome of the ajmaline challenge yielded 92% sensitivity (11/12) and 100% specificity (2/2).

Conclusion: In Brugada patients, ajmaline challenge elicits significant T wave amplitude changes within the ICD IEGM, greater than those of the IEGM ST segment. This study is the first step to provide new tools able to continuously monitor the type I Brugada aspect in patients affected by the Brugada syndrome.

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/eut294DOI Listing

Publication Analysis

Top Keywords

wave amplitude
24
ajmaline challenge
20
brugada syndrome
16
iegm wave
16
patients
12
amplitude changes
12
iegm segment
12
ajmaline
9
intracardiac electrogram
8
syndrome patients
8

Similar Publications

Evidence suggests that attenuated mismatch negative (MMN) waves have a close link to auditory verbal hallucinations (AVH) and their clinical outcomes, especially impaired neural oscillations such as θ, β representing attentional control. In current study, thirty patients with schizophrenia and AVH (SZ) and twenty-nine healthy controls (HC) underwent multi-feature MMN paradigm measurements including frequency and duration deviant stimuli (fMMN and dMMN). Clinical symptoms and MMN paradigm were followed up among SZ group after 8-week treatment.

View Article and Find Full Text PDF

Objective: To observe and measure the morphological and temporal evolutionary features of the hypersynchronous (HYP) pattern in the mesial temporal seizure.

Methods: The HYP patterns during preictal and interictal states of 16 mesial temporal epileptic patients were analyzed. The wave components of the HYP transients were firstly observed and measured.

View Article and Find Full Text PDF

Carbon Black Absorption Enhanced Fiber-Optic Photoacoustic Gas Sensing System with Ultrahigh Sensitivity.

Anal Chem

January 2025

School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.

A highly sensitive trace gas sensing system based on carbon black absorption enhanced photoacoustic (PA) spectroscopy (PAS) is reported. A carbon black sheet and a fiber-optic cantilever microphone (FOCM) are integrated to form a fiber-optic cantilever spectrophone (FOCS). The gas concentration is obtained by measuring the acoustic wave amplitude generated by the carbon black sheet, which absorbs the laser passing through the interest gas.

View Article and Find Full Text PDF

To enhance the safety of coal mining operations and improve the efficiency of gas extraction, hydraulic flushing technology has been widely used in low permeability coal seams. This study aims to investigate the mechanism of hydraulic flushing by conducting experiments focusing on four aspects: sample strength, punching pressure, punching position and vibration direction. The results show that an increase in hydraulic flushing pressure leads to a deeper impact groove, whereas higher sample strength results in a shallower groove.

View Article and Find Full Text PDF

In order to solve the problem of logging calibration without a free pipe in the process of acoustic variable density logging and the subjective problem of the free pipe calibration method, this paper studies an attenuation rate calibration method based on acoustic variable density logging. Using the developed acoustic wave probe response relationship device and the acoustic wave probe calibration device, the response consistency of the receiving probe of the acoustic wave instrument and the frequency of the transmitting probe can be calibrated in the laboratory, and the response consistency and frequency calibration coefficient can be obtained. Through this coefficient, the acoustic wave attenuation rate can be derived.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!