Aims: The objective of this study was to correlate the electrocardiogram (ECG) modification during an Ajmaline challenge in patients affected by the Brugada syndrome and implanted with an implantable cardioverter-defibrillator (ICD) with the morphological changes of their ICD's intracardiac electrogram (IEGM).
Methods And Results: Sixteen type 1 Brugada syndrome patients implanted with a St Jude Medical AnalyST(®) ICD were enrolled and underwent ajmaline challenge. Intracardiac electrograms and 12 lead ECG signals were collected over the duration of the study and analysed off-line. The right precordial ECG leads were in both the third and fourth intercostal space by putting V5 and V6 in V1 and V2 at the third intercostal space. Two patients were excluded from the analysis due to signal noise issues. Of the remaining 14 patients, 12 and 2 patients were adjudicated to have positive and negative ajmaline challenges, respectively, based on standard ECG criteria. In the ajmaline positive patients, the IEGM T wave amplitude changes were more prominent than those of the IEGM ST segment (-898 ± 463 vs. -55 ± 381 µV, P < 0.05). Furthermore, all of these T wave amplitude changes were in the negative polarity, whereas the change in polarity of the ST segment was mixed. The changes in the IEGM T wave amplitude and ST segment were significantly smaller in the ajmaline negative patients compared with those in the ajmaline positive patients [211 ± 158 (P < 0.05) and 107 ± 54 (P < 0.05) µV, respectively). Over all 14 analysable patients, the change in the ECG ST segment over the timecourse of the ajmaline challenge correlated better with the IEGM T wave amplitude change (R = 0.72 ± 0.33) than the IEGM ST segment change (R = 0.63 ± 0.33). Applying an IEGM T wave amplitude change cut-off of 400 µV for predicting the outcome of the ajmaline challenge yielded 92% sensitivity (11/12) and 100% specificity (2/2).
Conclusion: In Brugada patients, ajmaline challenge elicits significant T wave amplitude changes within the ICD IEGM, greater than those of the IEGM ST segment. This study is the first step to provide new tools able to continuously monitor the type I Brugada aspect in patients affected by the Brugada syndrome.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/europace/eut294 | DOI Listing |
Schizophr Res Cogn
June 2025
Shanghai Key Laboratory of Psychotic Disorders, Shanghai Mental Health Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200030, PR China.
Evidence suggests that attenuated mismatch negative (MMN) waves have a close link to auditory verbal hallucinations (AVH) and their clinical outcomes, especially impaired neural oscillations such as θ, β representing attentional control. In current study, thirty patients with schizophrenia and AVH (SZ) and twenty-nine healthy controls (HC) underwent multi-feature MMN paradigm measurements including frequency and duration deviant stimuli (fMMN and dMMN). Clinical symptoms and MMN paradigm were followed up among SZ group after 8-week treatment.
View Article and Find Full Text PDFFront Neurol
January 2025
Department of Neurology, Xuanwu Hospital Capital Medical University, Beijing, China.
Objective: To observe and measure the morphological and temporal evolutionary features of the hypersynchronous (HYP) pattern in the mesial temporal seizure.
Methods: The HYP patterns during preictal and interictal states of 16 mesial temporal epileptic patients were analyzed. The wave components of the HYP transients were firstly observed and measured.
Anal Chem
January 2025
School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.
A highly sensitive trace gas sensing system based on carbon black absorption enhanced photoacoustic (PA) spectroscopy (PAS) is reported. A carbon black sheet and a fiber-optic cantilever microphone (FOCM) are integrated to form a fiber-optic cantilever spectrophone (FOCS). The gas concentration is obtained by measuring the acoustic wave amplitude generated by the carbon black sheet, which absorbs the laser passing through the interest gas.
View Article and Find Full Text PDFSci Rep
January 2025
Guizhou Mining Safety Science Research Institute Co., Ltd, Guiyang, 550025, China.
To enhance the safety of coal mining operations and improve the efficiency of gas extraction, hydraulic flushing technology has been widely used in low permeability coal seams. This study aims to investigate the mechanism of hydraulic flushing by conducting experiments focusing on four aspects: sample strength, punching pressure, punching position and vibration direction. The results show that an increase in hydraulic flushing pressure leads to a deeper impact groove, whereas higher sample strength results in a shallower groove.
View Article and Find Full Text PDFSci Rep
January 2025
Beijing Gilface Technology Co., Ltd., Beijing, 100012, China.
In order to solve the problem of logging calibration without a free pipe in the process of acoustic variable density logging and the subjective problem of the free pipe calibration method, this paper studies an attenuation rate calibration method based on acoustic variable density logging. Using the developed acoustic wave probe response relationship device and the acoustic wave probe calibration device, the response consistency of the receiving probe of the acoustic wave instrument and the frequency of the transmitting probe can be calibrated in the laboratory, and the response consistency and frequency calibration coefficient can be obtained. Through this coefficient, the acoustic wave attenuation rate can be derived.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!