We measured the photothermal lens signal in samples exhibiting high turbidity using a pump-probe scheme. We show that the photothermal lens signal properties remain nearly unchanged up to values of turbidity of 6 cm(-1) despite the signal reduction due to the decrease of excitation power associated to turbidity losses. The signal starts decreasing abruptly for values of turbidity larger than 6 cm(-1). Multiple light scattering yields a reduction of the temperature gradients, which results in a decrease of the effective signal. However, the signal-to-noise ratio remains above 50 for turbidity values of 9 cm(-1), which corresponds to a reduction of light transmission by more than four orders of magnitude. We report on the detection of the photothermal lens signal through a 2 mm layer of organic tissue with a signal-to-noise ratio of about 500. This technique appears promising for imaging applications in organic samples, which usually exhibit high turbidity for visible and near-infrared light.

Download full-text PDF

Source
http://dx.doi.org/10.1366/12-06970DOI Listing

Publication Analysis

Top Keywords

photothermal lens
16
lens signal
12
high turbidity
8
values turbidity
8
signal-to-noise ratio
8
signal
6
turbidity
6
photothermal
4
lens spectrometry
4
spectrometry measurements
4

Similar Publications

Aim: To investigate the biocompatibility and bacterial adhesion properties of light responsive materials (LRM) and analyze the feasibility and biosafety of employing LRM in the preparation of accommodative intraocular lenses (AIOLs).

Methods: Employing fundamental experimental research techniques, LRM with human lens epithelial cells (hLECs) and human retinal pigment epithelium cells (ARPE-19 cells) were co-cultured. Commercially available intraocular lenses (IOLs) were used as controls to perform cell counting kit-8 (CCK-8), cell staining under varying light intensities, cell adhesion and bacterial adhesion experiments.

View Article and Find Full Text PDF

Fabrication of highly biocompatible SiO@Au-BSA nanoconjugates: Towards a promising thermal therapy route.

J Photochem Photobiol B

December 2024

Centro de Investigación en Genética y Ambiente-Universidad Autónoma de Tlaxcala, Autopista San Martín-Tlaxcala Km 10.5, Ixtacuixtla, 90120 Tlaxcala, Mexico. Electronic address:

SiO@Au nanoshells have gained relevance in recent years, especially in biomedical areas, acting as thermal therapy agents due to their high capacity to absorb light and transform it into heat that increases the temperature of the medium. Therefore, it is important to develop methodological strategies to obtain stable, highly specific and biocompatible nanoparticles. In this work, the synthesis of core-shell structures based on SiO@Au is reported, where the growth a thin shell ⁓ 46 nm on silica platform was possible.

View Article and Find Full Text PDF

Optofluidic devices that dynamically respond to light stimuli have the potential to impart modern adaptive optics with intrinsic optical logic without the need for external power sources or feedback control. While photo actuation is typically associated with low energy efficiency compared with alternative modes of actuation, fluid lenses can be tuned with minimal work by generating small differential pressures across the surface of the lens to drive a change in focal length. In this study, we developed a wide aperture (9.

View Article and Find Full Text PDF

Features of High-Precision Photothermal Analysis of Liquid Systems by Dual-Beam Thermal Lens Spectrometry.

Nanomaterials (Basel)

October 2024

Analytical Chemistry Division, Chemistry Department, M.V. Lomonosov Moscow State University, d. 1, Str. 3, Lenin Hills, GSP-1 V-234, Moscow 119991, Russia.

Thermal lens spectrometry is a high-sensitivity method for measuring the optical and thermal parameters of samples of different nature. To obtain both thermal diffusivity and absorbance-based signal measurements with high accuracy and precision, it is necessary to pay attention to the factors that influence the trueness of photothermal measurements. In this study, the features of liquid objects are studied, and the influence of optical and thermal effects accompanying photothermal phenomena are investigated.

View Article and Find Full Text PDF
Article Synopsis
  • - Bacterial keratitis (BK), a serious eye infection linked to Staphylococcus aureus, is a major concern for contact lens users, threatening their vision.
  • - The study presents a new smart nanoplatform (deMS@cNF) made from demineralized mussel shells and chitin nanofibrils, which can disinfect contact lenses using heat generated by a bike flashlight.
  • - This nanoplatform not only proves to be biocompatible and non-toxic in tests, but also offers a cost-effective method of converting marine biowaste into a portable device for disinfecting lenses, indicating potential for broader antimicrobial uses.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!