A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Stochastic modeling of short-term exposure close to an air pollution source in a naturally ventilated room: an autocorrelated random walk method. | LitMetric

For an actively emitting source such as cooking or smoking, indoor measurements have shown a strong "proximity effect" within 1 m. The significant increase in both the magnitude and variation of concentration near a source is attributable to transient high peaks that occur sporadically-and these "microplumes" cause great uncertainty in estimating personal exposure. Recent field studies in naturally ventilated rooms show that close-proximity concentrations are approximately lognormally distributed. We use the autocorrelated random walk method to represent the time-varying directionality of indoor emissions, thereby predicting the time series and frequency distributions of concentrations close to an actively emitting point source. The predicted 5-min concentrations show good agreement with measurements from a point source of CO in a naturally ventilated house-the measured and predicted frequency distributions at 0.5- and 1-m distances are similar and approximately lognormal over a concentration range spanning three orders of magnitude. By including the transient peak concentrations, this random airflow modeling method offers a way to more accurately assess acute exposure levels for cases where well-defined airflow patterns in an indoor space are not available.

Download full-text PDF

Source
http://dx.doi.org/10.1038/jes.2013.63DOI Listing

Publication Analysis

Top Keywords

naturally ventilated
12
source naturally
8
autocorrelated random
8
random walk
8
walk method
8
actively emitting
8
frequency distributions
8
point source
8
source
5
stochastic modeling
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!