Design and fabrication of biosensing interface for waveguide-mode sensor.

Langmuir

Biomedical Research Institute, Advanced Industrial Science and Technology (AIST), Central 6, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8566, Japan.

Published: October 2013

In order to develop a biosensing system with waveguide-mode sensor, fabrication of a biosensing interface on the silica surface of the sensing chip was carried out using triethoxysilane derivatives with anti-leptin antibody. Triethoxysilane derivatives bearing succinimide ester and oligoethylene glycol moieties were synthesized to immobilize the antibody and to suppress nonspecific adsorption of proteins, respectively. The chip modified with triethoxysilane derivatives bearing oligoethylene glycol moiety suppressed nonspecific adsorption of proteins derived from human serum effectively by rinse with PBS containing surfactant (0.05% Tween 20). On the other hand, it was confirmed that antibody was immobilized on the chip by immersion into antibody solution to show response of antigen-antibody reaction, where the chip was modified with triethoxysilane derivatives bearing succinimide ester moiety. When the interface was fabricated with antibody and a mixture of triethoxysilane derivatives bearing succinimide ester and oligoethylene glycol moieties, the response of antigen-antibody reaction depended on composition of the mixture and enhanced with the increase of ratio for triethoxysilane derivatives bearing succinimide ester moiety reflecting the antibody concentration immobilized on the chip. While introduction of excess triethoxysilane derivatives bearing succinimide ester moiety induced nonspecific adsorption of proteins derived from human serum, the immobilized antibody on the chip kept its activity after 1-month storage in a refrigerator. Taking into consideration those factors, the biosensing interface was fabricated using triethoxysilane derivatives with anti-leptin antibody to examine performance of the waveguide-mode sensor. It was found that the detection limits for human leptin were 50 ng/mL in PBS and 100 ng/mL in human serum. The results demonstrate that the waveguide-mode sensor powered by the biosensing interface fabricated with those triethoxysilane derivatives and antibody has potential to detect several tens of nanograms per milliliter of biomarkers in human serum with an unlabeled detection method.

Download full-text PDF

Source
http://dx.doi.org/10.1021/la402802uDOI Listing

Publication Analysis

Top Keywords

triethoxysilane derivatives
36
derivatives bearing
24
bearing succinimide
20
succinimide ester
20
biosensing interface
16
waveguide-mode sensor
16
human serum
16
oligoethylene glycol
12
nonspecific adsorption
12
adsorption proteins
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!