Background: Hospital pharmacists and pharmacy technicians play a major role in detecting prescribing errors by medication surveillance. At present the frequency of detected and correctly handled prescribing errors is unclear, as are factors associated with correct handling.

Objective: To examine the frequency of detection of prescribing errors and the frequency of correct handling, as well as factors associated with correct handling of prescribing errors by hospital pharmacists and pharmacy technicians.

Setting: This study was conducted in 57 Dutch hospital pharmacies.

Method: Prospective observational study with test patients, using a case-control design to identify factors associated with correct handling. A questionnaire was used to collect the potential factors. Test patients containing prescribing errors were developed by an expert panel of hospital pharmacists (a total of 40 errors in nine medication records divided among three test patients; each test patient was used in 3 rounds; on average 4.5 prescribing error per patient per round). Prescribing errors were defined as dosing errors or therapeutic errors (contra-indication, drug-drug interaction, (pseudo)duplicate medication). The errors were selected on relevance and unequivocalness. The panel also defined how the errors should be handled in practice using national guidelines and this was defined as 'correct handling'. The test patients had to be treated as real patients while conducting medication surveillance. The pharmacists and technicians were asked to report detected errors to the investigator.

Main Outcome Measure: The percentages of detected and correctly handled prescribing errors were the main outcome measures. Factors associated with correct handling were determined, using multivariate logistic regression analysis.

Results: Fifty-nine percent of the total number of intentionally added prescribing errors were detected and 57 % were handled correctly by the hospital pharmacists and technicians. The use of a computer system for medication surveillance compared to no computer system was independently associated with correct handling [odds ratio (OR) 15.39 (95 % confidence interval (CI) 3.62-65.50] for computerized physician order entry system; OR 15.40 (95 % CI 3.61-65.70) for order entry by pharmacy technicians), but because the reference category contained only one hospital these results can't be interpreted. Furthermore, manual screening of dosages in children with or without computerized surveillance compared to no dosage checks for children [OR 2.02 (95 % CI 1.06-3.84)], qualified pharmacy technicians compared to no qualified pharmacy technicians [OR 1.32 (95 % CI 1.03-1.67)] and pharmacy technicians using protocols compared to ones not using protocols [OR 1.30 (95 % CI 1.04-1.61)] were independently associated with correct handling.

Conclusion: This study showed that the quality of medication surveillance in Dutch hospital pharmacies can be subject to improvement and the identified factors may give direction to such improvements.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11096-013-9848-yDOI Listing

Publication Analysis

Top Keywords

prescribing errors
36
correct handling
24
associated correct
24
test patients
20
pharmacy technicians
20
hospital pharmacists
16
medication surveillance
16
factors associated
16
errors
15
dutch hospital
12

Similar Publications

Pharmacists have often been viewed as the last line of defence against prescription errors in traditional care models. Although a large number of chronic care patients are using telehealth services to increase their access to continuous care, researchers have yet to investigate prescription safety in such settings in Australia. The absence of this literature is particularly concerning in the context of the Australian Government's admission in a 2024 report that the national health system has not adequately addressed the World Health Organization's 'Medication without harm' objective.

View Article and Find Full Text PDF

Quantifying the mechanical properties of coronary arterial walls could provide meaningful information for the diagnosis, management, and treatment of coronary artery diseases. Since patient-specific coronary samples are not available for patients requiring continuous monitoring, direct experimental testing of vessel material properties becomes impossible. Current coronary models typically use material parameters from available literature, leading to significant mechanical stress/strain calculation errors.

View Article and Find Full Text PDF

Medication errors continue to pose a significant risk to patient safety, accounting for half of the avoidable harm in healthcare systems around the world. In emergency departments (EDs), factors such as high patient loads and emergent nature of care increase the likelihood of such errors. An audit conducted at the ED of Changi General Hospital Singapore from January 2019 to July 2022 revealed that the duplicate therapy error comprised 31% of all reported medication errors.

View Article and Find Full Text PDF

Artificial Intelligence-Empowered Multistep Integrated Radiation Therapy Workflow for Nasopharyngeal Carcinoma.

Int J Radiat Oncol Biol Phys

December 2024

Department of Radiation Oncology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangzhou, China. Electronic address:

Purpose: To establish an artificial intelligence (AI)-empowered multistep integrated (MSI) radiation therapy (RT) workflow for patients with nasopharyngeal carcinoma (NPC) and evaluate its feasibility and clinical performance.

Methods And Materials: Patients with NPC scheduled for MSI RT workflow were prospectively enrolled. This workflow integrates RT procedures from computed tomography (CT) scan to beam delivery, all performed with the patient on the treatment couch.

View Article and Find Full Text PDF

Appropriate use of single-dose injectable aripiprazole lauroxil in the treatment of schizophrenia.

Ment Health Clin

December 2024

(Corresponding author) Associate Professor, Department of Clinical and Administrative Pharmacy, College of Pharmacy, University of Georgia, Athens, GA,

Introduction: Single-dose injectable aripiprazole lauroxil (SDIAL) is used with long-acting injectable (LAI) aripiprazole lauroxil in the treatment of schizophrenia. SDIAL can be used to either initiate treatment or supplement during maintenance when follow-up doses are not given within labeling recommendations. The primary objective was to determine the usage and appropriateness of SDIAL between the initiation and the maintenance supplementation use in a Medicaid database.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!