A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validation of blood pressure monitoring using pulse transit time in heart failure patients with Cheyne-Stokes respiration undergoing adaptive servoventilation therapy. | LitMetric

Purpose: Using pulse transit time (PTT) and an ECG appears to be a promising alternative for invasive or noninvasive monitoring of blood pressure (BP). This study assessed the validity of PTT for BP monitoring in clinical practice.

Methods: Twenty-nine patients with chronic heart failure (HF; 27 male, 70.5 ± 9.9 years) and nocturnal Cheyne-Stokes respiration were noninvasively ventilated for one hour using adaptive servoventilation (ASV) therapy (PaceWave, ResMed). BP was measured using two devices (oscillometrically via Task Force Monitor, CNSystems and PTT via SOMNOscreen, Somnomedics) at least every 7 min for 30 min before, during, and after ASV.

Results: Mean systolic BP was 118.1 ± 14.4 mmHg vs. 115.9 ± 14.1 mmHg for oscillometric method vs PTT, respectively. Corresponding values for diastolic BP were 72.3 ± 10.3 mmHg and 69.4 ± 11.1 mmHg. While clinically comparable, differences between the two methods were statistically significant (p < 0.05). The difference between the two methods showed an increasing trend over time. A total of 18.5 % of PTT-based measurements could not be analyzed. The direction of a change in BP was opposite for PTT vs oscillometry for 17.0 % and 32.8 % of systolic and diastolic BP measurements, respectively.

Conclusions: When monitoring BP in HF patients, overall BP monitoring using PTT is comparable to oscillometry for a period of 2 h (including a 1-h ASV phase). However, PTT shows a tendency to underestimate BP over time and during ASV.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11325-013-0895-3DOI Listing

Publication Analysis

Top Keywords

blood pressure
8
pulse transit
8
transit time
8
heart failure
8
cheyne-stokes respiration
8
adaptive servoventilation
8
validation blood
4
pressure monitoring
4
monitoring pulse
4
time heart
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!