Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Perfusion index (PI) could reflect peripheral flow. Preterm infants with hemodynamically significant patent ductus arteriosus (hsPDA) will have left-to-right shunt across PDA causing less blood flow to the lower legs.
Objective: To evaluate pre- and postductal PI differences (ΔPI) in hsPDA.
Methods: Preterm infants with gestational age <34 weeks were assessed for ΔPI on days 1, 3, and 7 of life with simultaneous echocardiography. Based on echocardiography, each infant was categorized into hsPDA, non-hsPDA, and no PDA.
Results: Thirty infants (16 males), median age 31 weeks (interquartile range, IQR, 29-32) and weight 1,490 g (IQR 1,100-1,670) were enrolled. On days 1 and 3 of life, the ΔPI of infants with hsPDA (1.57%, IQR 0.28-2.32, n = 14, and 1.32%, IQR 0.28-1.83, n = 10) were significantly higher than those without hsPDA (0.14%, IQR -0.03 to 0.30, n = 16, and 0.08%, IQR -0.07 to 0.26, n = 20), p = 0.009 and 0.005, respectively. At all time points (days 1, 3, and 7 of life, n = 84), ΔPI >1.05% had sensitivity, specificity, positive predictive value, and negative predictive value of 66.7, 100, 100, and 86.4%, respectively, to detect hsPDA.
Conclusion: The pre- and postductal PI differences were significantly related to the hemodynamic changes of PDA and might be useful to detect hemodynamically significant PDA.