A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 143

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: Attempt to read property "Count" on bool

Filename: helpers/my_audit_helper.php

Line Number: 3100

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Survival of incident patients on high-volume online hemodiafiltration compared to low-volume online hemodiafiltration and high-flux hemodialysis. | LitMetric

AI Article Synopsis

  • Hemodiafiltration (oHDF) is gaining popularity as a dialysis treatment, with the volume of substitution fluid considered a key factor influencing patient survival.
  • * The study analyzed 442 hemodialysis and oHDF patients across several NephroCare centers from 2007 to 2011, focusing on survival rates based on different substitution fluid volumes.
  • * Results indicated that patients on high-volume oHDF had significantly lower mortality risk compared to those on high-flux hemodialysis, while low-volume oHDF did not show a significant advantage.

Article Abstract

Background: Hemodiafiltration is becoming a preferred treatment modality for dialysis patients in many countries. The volume of substitution fluid delivered has been indicated as an independent mortality risk factor. The aim of this study is to compare patient survival on three different treatment modalities: high-flux hemodialysis, low-volume online HDF (oHDF) and high-volume oHDF.

Methods: Incident hemodialysis and oHDF patients treated in 13 NephroCare centers in Bosnia and Herzegovina, Serbia and Slovenia between January 1, 2007, and December 31, 2011, were included in this epidemiological cohort study. High-volume oHDF was defined as substitution volume higher than the median substitution volume infused, otherwise low-volume. Main predictor was treatment modality at baseline and in time-dependent model. Other predictors were age, gender, diabetes mellitus, cerebrovascular accident, arrhythmia, hemoglobin and C-reactive protein.

Results: Four hundred and forty-two patients were included in the study. Median substitution fluid volume was 20.4 L. Mean difference between the oHDF groups in substitution fluid volume was 8.3 ± 5.2 L [95 % confidence intervals (95 % CI) 7.1-9.5, p < 0.0001]. The unadjusted hazard ratios (HR) with 95 % CI compared to high-flux HD were 0.87 (0.5-1.5) for low-volume oHDF and 0.29 (0.13-0.63) for high-volume oHDF. After the adjustment for covariates, the HR for patients on low-volume oHDF remained statistically insignificant compared to high-flux HD (0.84; 95 % CI 0.46-1.53), while patients on high-volume oHDF showed a marked and significantly lower HR (0.29; 95 % CI 0.13-0.68) than patients on high-flux HD in baseline model. While this effect failed to reach significance in the time-dependent model (HR 0.477; 95 % CI 0.196-1.161), possibly due to an inadequate sample size here, the consistency of results in both models supports the robustness of the findings. After switching from high-flux hemodialysis to oHDF, mean hemoglobin and albumin levels did not change significantly. Mean erythropoietin resistance index (ERI) and erythropoiesis stimulating agents (ESA) consumption decreased significantly (p = 0.02, p = 0.03, respectively).

Conclusions: The median substitution volume used in these three countries for post-dilutional oHDF is 20.4 L. oHDF is associated with significant reductions in ERI and ESA consumption. Only high-volume oHDF is associated with improved survival compared to high-flux hemodialysis.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11255-013-0526-8DOI Listing

Publication Analysis

Top Keywords

high-flux hemodialysis
16
high-volume ohdf
16
substitution fluid
12
ohdf
12
substitution volume
12
median substitution
12
compared high-flux
12
patients high-volume
8
online hemodiafiltration
8
low-volume online
8