A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Method for determining o-tolidine in workplace air by gas chromatography]. | LitMetric

[Method for determining o-tolidine in workplace air by gas chromatography].

Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi

Nanjing Center for Disease Control and Prevention, Nanjing, Jiangsu 210003, China.

Published: August 2013

Objective: To establish a method for determining o-tolidine in workplace air by gas chromatography.

Methods: o-tolidine in workplace air was collected with a glass fiber filter, desorbed with methanol, and determined by gas chromatography-flame ionization detector.

Results: The concentration of o-tolidine showed a linear relationship with peak area within 0.04∼9.00 µg/ml; the detection limit was 0.04 µg/ml; the minimum detectable concentration was 0.0002 mg/m(3) (calculated by 375 L air sample); the sampling efficiency was 93%∼100%; the elution efficiency was 94%∼96%; the relative standard deviation was 0.8-2.5%. Sample could be stored at 4 °C for at least 8 days and at room temperature for as long as 6 days.

Conclusion: This determination method meets the requirements of Guide for establishing occupational heath standards-Part 4 Determination methods of air chemicals in workplace (GBZ/T 210.4-2008) and is suitable for determination of o-tolidine in workplace air.

Download full-text PDF

Source

Publication Analysis

Top Keywords

o-tolidine workplace
16
workplace air
16
determining o-tolidine
8
air gas
8
air
6
o-tolidine
5
workplace
5
[method determining
4
gas chromatography]
4
chromatography] objective
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!