A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of epsilon aminocaproic acid and tranexamic Acid in thoracic aortic surgery: clinical efficacy and safety. | LitMetric

Objective: To evaluate the efficacy and safety of tranexamic acid (TXA) versus epsilon aminocaproic acid (EACA) in patients undergoing thoracic aortic surgery.

Design: A prospective randomized study.

Setting: A tertiary care center.

Participant: The study was conducted on 64 consecutive adult patients undergoing thoracic aortic surgery with cardiopulmonary bypass (CPB).

Interventions: Group EACA received a bolus of 50 mg/kg of EACA after induction of anesthesia over 20 minutes followed by maintenance infusion of 25 mg/kg/h until chest closure. Group TXA received a bolus of 10 mg/kg of TXA after induction of anesthesia over 20 minutes followed by maintenance infusion of 1 mg/kg/h until chest closure.

Measurements And Main Results: Cumulated mean blood loss, total packed red blood cells, and blood product requirement up to 24 h postoperatively were comparable between groups. A significant renal injury (EACA 40% v TXA 16%; p = 0.04) and increased tendency for renal failure (EACA 10% v TXA 0%, p = 0.11; relative risk 2.15) were observed with EACA compared to TXA. There was increased tendency of seizure with TXA (EACA v TXA: 3.3% v 10%; p>0.05, relative risk 1.53). There was significant increase in the D-dimer from preoperative to postoperative values in Group EACA. (p< 0.01).

Conclusions: Both EACA and TXA were equally effective in reducing the perioperative blood loss and transfusion requirement in patients undergoing thoracic aortic surgery. While significant renal injury was observed with EACA, there was a tendency for higher incidence of seizure with TXA. Prospective placebo-controlled trials recruiting larger sample size using sensitive biomarkers are required before any recommendations.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.jvca.2013.04.003DOI Listing

Publication Analysis

Top Keywords

thoracic aortic
16
aortic surgery
12
patients undergoing
12
undergoing thoracic
12
txa
10
eaca
10
epsilon aminocaproic
8
aminocaproic acid
8
tranexamic acid
8
efficacy safety
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!