Purpose: Few studies have investigated the marginal accuracy of 3-unit zirconia fixed partial dentures (FPDs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) system. The purpose of this study was to compare the marginal fit of zirconia FPDs made using two CAD/CAM systems with that of metal-ceramic FPDs.

Materials And Methods: Artificial resin maxillary central and lateral incisors were prepared for 3-unit FPDs and fixed in yellow stone. This model was duplicated to epoxy resin die. On the resin die, 15 three-unit FPDs were fabricated per group (45 in total): Group A, zirconia 3-unit FPDs made with the Everest system; Group B, zirconia 3-unit FPDs made with the Lava system; and Group C, metal-ceramic 3-unit FPDs. They were cemented to resin dies with resin cement. After removal of pontic, each retainer was separated and observed under a microscope (Presize 440C). Marginal gaps of experimental groups were analyzed using one-way ANOVA and Duncan test.

Results: Mean marginal gaps of 3-unit FPDs were 60.46 µm for the Everest group, 78.71 µm for the Lava group, and 81.32 µm for the metal-ceramic group. The Everest group demonstrated significantly smaller marginal gap than the Lava and the metal-ceramic groups (P<.05). The marginal gap did not significantly differ between the Lava and the metal-ceramic groups (P>.05).

Conclusion: The marginal gaps of anterior 3-unit zirconia FPD differed according to CAD/CAM systems, but still fell within clinically acceptable ranges compared with conventional metal-ceramic restoration.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3774934PMC
http://dx.doi.org/10.4047/jap.2013.5.3.219DOI Listing

Publication Analysis

Top Keywords

3-unit fpds
20
cad/cam systems
12
marginal gaps
12
marginal fit
8
3-unit
8
anterior 3-unit
8
fixed partial
8
3-unit zirconia
8
fpds
8
fpds fabricated
8

Similar Publications

Article Synopsis
  • The study aimed to evaluate how different printing orientations affect the fit and gaps of a 3-unit interim fixed partial denture created using two additive manufacturing methods compared to traditional milling.
  • A digital design was printed using stereolithography (SLA) and digital light processing (DLP) technologies, with measurements taken for gaps in various orientations, while milling served as a control.
  • Results indicated that SLA produced comparable fit to milling across all orientations, whereas DLP showed significantly larger gaps, suggesting SLA is more reliable for dental applications.
View Article and Find Full Text PDF

Purpose: To investigate the influence of cantilever prosthetic arm on the marginal bone loss (MBL) over time around dental implants supporting short fixed partial dentures (FPDs), in a record-based retrospective study.

Methods: All cases of 3-unit implant-supported FPDs, supported by 2-3 implants, from the database of cases treated at one specialist clinic were considered for inclusion. Only implants with a minimum of 36 months of radiological follow-up were considered.

View Article and Find Full Text PDF

Statement Of Problem: Strength-gradient zirconia combining 3 zirconia formulations with different flexural strengths has been reported to have outstanding mechanical properties. However, data concerning the effect of different sintering protocols on the fracture strength of 3-unit monolithic gradient zirconia fixed partial dentures (FPDs) are sparse.

Purpose: The purpose of this in vitro study was to test the effect of different sintering protocols on the fracture strength of 3-unit monolithic gradient zirconia FPDs.

View Article and Find Full Text PDF

Retrospective clinical study of 1472-unit monolithic zirconia restorations with feather-edge margins realized with digital workflow.

Clin Oral Investig

November 2023

Department of Neuroscience, School of Dentistry, Division of Prosthodontics and Digital Dentistry, University of Padova, Padova, Italy.

Objectives: To evaluate the clinical performance of monolithic zirconia restorations with feather-edge margins fabricated by digital impressions.

Materials And Methods: All participants that present monolithic zirconia restorations with feather-edge margins realized with digital workflow were evaluated during scheduled periodontal maintenance between February and September 2022 according to predetermined inclusion criteria. Clinical performance was assessed using the modified USPHS and periodontal parameters.

View Article and Find Full Text PDF

Purpose: To evaluate the vertical misfit, stress distribution around dental implants, and cantilever fracture strength of 3-unit implant-supported cantilever fixed partial dentures (FPDs) using frameworks made from different materials and manufacturing techniques.

Materials And Methods: Forty FPDs were fabricated and divided into 5 groups (n = 8) based on the framework material used: LAS Co-Cr (Conventional casting-laser welding); TIG Co-Cr (Conventional casting -TIG welding); OP Co-Cr (Conventional casting-one-piece); CAD Co-Cr (CAD-CAM); and CAD Zr (CAD-CAM ZrO). The vertical misfit was evaluated before porcelain application (T1) and before (T2), and after thermomechanical cycling (T3) by stereomicroscopy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!