AI Article Synopsis

  • Nipple-sparing mastectomies (NSM) are increasingly common in breast cancer treatment, but complications related to blood flow to the nipple-areolar complex (NAC) occur in 3-37% of patients.
  • Intraoperative monitoring using indocyanine green (ICG) and infrared imaging helps evaluate blood flow patterns to classify perfusion into three categories: V1 (breast tissue), V2 (surrounding skin), and V3 (both).
  • Results from 39 breasts showed that the V1 pattern had the highest rate of ischemia, indicating that monitoring perfusion can guide surgical decisions and reduce complications during NSM procedures.

Article Abstract

Background: Nipple-sparing mastectomies (NSM) have gained acceptance in the field of breast oncology. Ischemic complications involving the nipple-areolar complex (NAC) occur in 3-37 % of cases. Skin perfusion can be monitored intraoperatively using indocyanine green (IC-GREEN™, ICG) and a specialized infrared camera-computer system (SPY Elite™). The blood flow pattern to the breast skin and the NAC were evaluated and a classification scheme was developed.

Methods: Preincision baseline and postmastectomy skin perfusion studies were performed intraoperatively using 3 mL of ICG. The pattern of arterial blood inflow was classified according to whether perfusion appeared to originate predominantly from the underlying breast tissue (V1), the surrounding skin (V2), or a combination of V1 and V2 (V3). Ischemia, resection, or delayed complications of NAC were recorded.

Results: Thirty-nine breasts were interrogated. Seven (18 %) demonstrated a V1 pattern, 18 (46 %) a V2 pattern, and 14 (36 %) a V3 pattern. Seven (18 %) NACs were removed; six intraoperatively and the seventh in a delayed fashion. Notably, five of the seven resected NACs had a V1 pattern. Overall, 71 % of all V1 cases demonstrated profound ischemic changes by intraoperative clinical judgment and SPY imaging. The rates of resection of the NAC differed significantly between perfusion patterns (Fisher's exact test, p = 0.0003).

Conclusions: Three perfusion patterns for the NAC are defined. The V1 pattern had the highest rate of NAC ischemia in NSM. Imaging NAC and skin perfusion during NSMs is a useful adjunctive tool with potential to direct placement of mastectomy incisions and minimize ischemic complications.

Download full-text PDF

Source
http://dx.doi.org/10.1245/s10434-013-3214-0DOI Listing

Publication Analysis

Top Keywords

perfusion patterns
12
ischemic complications
12
skin perfusion
12
nipple-sparing mastectomies
8
pattern pattern
8
perfusion
7
nac
7
pattern
7
skin
5
intraoperative imaging
4

Similar Publications

Objectives: Phosphorus-31 magnetic resonance spectroscopic imaging (P-MRSI) is a non-invasive tool for assessing cellular high-energy metabolism in-vivo. However, its acquisition suffers from a low sensitivity, which necessitates large voxel sizes or multiple averages to achieve an acceptable signal-to-noise ratio (SNR), resulting in long scan times.

Materials And Methods: To overcome these limitations, we propose an acquisition and reconstruction scheme for FID-MRSI sequences.

View Article and Find Full Text PDF

One of the key factors of the interaction 'osteoplastic material-organism' is the state of the implant surface. Taking into account the fact that the equilibrium in regeneration conditions is reached only after the reparative histogenesis process is completed, the implant surface is constantly modified. This work is devoted to the numerical description of the dynamic bilateral material-medium interaction under close to physiological conditions, as well as to the assessment of the comparability of the model with and experimental results.

View Article and Find Full Text PDF

BACKGROUND Solitary thyroid nodules present a challenge in differentiating between benign and malignant conditions using ultrasound (US). Arrival time parameter imaging (At-PI) following contrast-enhanced ultrasound (CEUS) can effectively visualize the vascular architectural patterns of the nodules, providing valuable diagnostic information. This study aimed to explore the application value of At-PI in differentiating thyroid nodules, specifically focusing on a sample of 127 cases.

View Article and Find Full Text PDF

Diabetic macular edema (DME) is a vision-threatening complication of diabetic retinopathy and causes significant morbidity in patients. Anti-vascular endothelial growth factor (VEGF) agents are the mainstay of treatment for DME, with steroid implants being used for the treatment of anti-VEGF resistant eyes. Over the years, several classification systems have been devised to describe the patterns of DME using optical coherence tomography (OCT).

View Article and Find Full Text PDF

Comparison of retinal vascular abnormalities in the fellow eyes of children with Coats' disease and normal subjects using ultra-widefield fundus fluorescein angiography.

Photodiagnosis Photodyn Ther

December 2024

Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China; Beijing Ophthalmology and Visual Science Key Laboratory, Beijing 100730, China. Electronic address:

Purpose: To investigate retinal vascular abnormalities in the affected and fellow eyes of children with Coats' disease using Optos® ultra-widefield fundus fluorescein angiography (UWFFA) and compare the peripheral vascular abnormalities between fellow eyes and normal control eyes.

Methods: Children diagnosed with Coats' disease who underwent UWFFA were retrospectively reviewed. Healthy eyes with complete UWFFA data were selected as controls.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!