Purpose: To evaluate multi-institutional prostate brachytherapy dosimetric quality using multisector analysis.
Methods And Materials: In the database, 4547 patients underwent brachytherapy (3094 for (125)I, 1437 for (103)Pd, and 16 for (131)Cs). The original prostate postimplant dosimetry was reported using the maximum dose covering 90% of the prostate volume (D90) and the percentage of the prostate volume covered by the prescription dose (V100). Retrospectively, the dosimetry of all implants was recalculated after segmenting the prostate into 12 sectors (anterior, left and right lateral and posterior, about the center of gravity, and subdivided lengthwise into three-base, midgland, and apex). The dosimetric quality of each sector and combinations of sectors was compared across radionuclides.
Results: For each radionuclide, there was no significant difference between monotherapy and boost in terms of V100 or D90. When classified as excellent (V100 ≥ 90%), standard (V100 ≥ 80%), or minimal (V100 < 80%), 33.0%, 4.6%, and 10.5% of all base, midgland, and apical sectors, respectively, were of minimal quality. Specifically, 59.2% of the anterior base and 30.3% of the posterior base sectors were minimal. At the anterior midgland and apex, 22% and 19% of sectors were minimal. Excellent quality was observed in more than 90% of lateral and posterior midgland sectors and in >70% of lateral and posterior sectors. When stratified by (103)Pd vs. (125)I, sector analysis did not result in clinically significant dosimetric differences.
Conclusions: Coverage of base sectors was inferior to midgland and apical sectors, and coverage of anterior sectors was notably inferior to lateral and posterior sectors. Further critique of brachytherapy planning and intraoperative technique is necessary for brachytherapists to minimize these dosimetric differences.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.brachy.2013.08.003 | DOI Listing |
Health Phys
January 2025
Department of Radiation Oncology, Medicine Faculty of Van Yüzüncü Yıl University, Van, Turkey.
Quality assurance practices performed before treatment are believed to identify various potential errors. In this study, 2-dimensional (2D) dosimetric results were analyzed by making some intentional mistakes in six different treatment plans. In this way, the detectability of errors was investigated.
View Article and Find Full Text PDFFront Oncol
December 2024
Institute of Radiation Medicine (IRM), Helmholtz Zentrum München GmbH, German Research Center for Environmental Health, Neuherberg, Germany.
In Vivo
December 2024
Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.
Background/aim: HyperArc (HA) is an automated planning technique enabling single-isocenter brain stereotactic radiotherapy (SRT); however, dosimetric outcomes may be influenced by the planner's expertise. This study aimed to assess the impact of institutional experience on the plan quality of HA-SRT for both single and multiple brain metastases.
Materials And Methods: Twenty patients who underwent HA-SRT for single metastasis between 2020 and 2021 comprised the earlier group, while those treated between 2022 and 2024 constituted the later group.
Sci Rep
December 2024
Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, 310000, China.
Recently, neoadjuvant short-course radiation therapy (SCRT) has emerged as a valid treatment option for patients with locally advanced rectal cancer (LARC). We assessed SCRT plans using volumetric-modulated arc therapy (VMAT) with Halcyon and Infinity medical linear accelerators (Linacs) and compared the plan quality and delivery efficiency across all cases. Thirty patients who underwent preoperative SCRT for LARC at the hospital were randomly selected.
View Article and Find Full Text PDFPeerJ
December 2024
Department of Radiation Oncology, The First Affiliated Hospital of Guangzhou Medical University, GuangZhou, GuangDong, China.
Background: This study investigates the impact of convergence mode (CM) in Eclipse (Varian Medical Systems) on the quality and complexity of volumetric modulated arc therapy (VMAT) plans for nasopharyngeal carcinoma (NPC) patients.
Methods: We retrospectively analyzed data from 21 NPC patients. For each patient, three VMAT plans with different CM settings (Off, On, and Extended) were created using identical optimization objectives.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!