A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

ActiGraph™ activity monitors: "the firmware effect". | LitMetric

Purpose: The objective of this study is to examine the effect of different firmware versions on ActiGraph™ counts from the laboratory, field, and mechanical shaker testing.

Methods: Counts from 5 GT3X and 7 GT1M firmware versions were compared in this study. Monitors uploaded with these firmware versions were worn on the hip by 15 participants (age = 24.9 ± 5.0 yr, BMI= 23.9 ± 2.4 kg · m(-2)) who performed laboratory-based treadmill (walking: 1.5, 3.0 and 4.5 mph; running: 6 mph) and simulated free-living activities (sitting, self-paced walking, filing papers, dusting, vacuuming, and cleaning the room). Testing was also conducted during 1 d of free living and using orbital mechanical shaker testing at 0.7, 1.3, 2.0, and 3.0 Hz. Intermonitor comparisons for vertical, anteroposterior, mediolateral, and triaxial vector magnitude counts were conducted using one-way ANOVA and post hoc pairwise comparisons (P < 0.05).

Results: Vertical counts during treadmill walking at 1.5 mph from the GT1M monitor with firmware version 1.1.0. were significantly greater (P < 0.05; 75%) than output from the monitor with firmware version 1.3.0. Shaker testing revealed statistically significant differences in vertical and lateral counts. Although there were no significant differences among activity counts in the free-living comparisons, firmware version 1.1.0. produced the highest vertical counts during this protocol.

Conclusion: Greater sensitivity of firmware version 1.1.0. to low-frequency sedentary activities resulted in greater counts than other firmware versions. It is recommended that before releasing new firmware, ActiGraph™ perform both human and mechanical shaker testing to verify comparability in outputs between new and previous firmware versions.

Download full-text PDF

Source
http://dx.doi.org/10.1249/MSS.0000000000000145DOI Listing

Publication Analysis

Top Keywords

firmware versions
20
firmware version
16
mechanical shaker
12
shaker testing
12
version 110
12
firmware
11
counts
8
treadmill walking
8
walking mph
8
vertical counts
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!