Comparison of thermoregulatory devices used during anesthesia of C57BL/6 mice and correlations between body temperature and physiologic parameters.

J Am Assoc Lab Anim Sci

University Laboratory Animal Resources, University of Pennsylvania, Philadelphia, Pennsylvania, USA; Department of Pathobiology, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.

Published: September 2013

General anesthesia affects several body systems, including thermoregulation. Decreased body temperature during anesthesia has potential negative effects, including delayed recovery to consciousness. Thermoregulatory support devices are used to maintain temperature in anesthetized rodents. We analyzed 2 novel thermoregulatory devices, thermogenic gel packs and reflective foils, to compare their effectiveness in maintaining temperatures with that of a standard circulating-warm-water blanket (CWWB) in C57BL/6 mice. Mice were grouped randomly: control (no thermal support), reflective foil, gel pack, gel pack plus reflective foil, CWWB on medium setting, CWWB on high setting, and CWWB on high setting plus reflective foil. Mice were anesthetized with isoflurane for 30 min, and temperature and heart and respiratory rates were monitored. Results indicated that the temperatures of mice with reflective foil only (start temperature, 36.2 ± 0.38 °C; end temperature, 28.8 ± 0.78 °C) did not differ significantly from those of control mice; however, the inclusion of foil heightened thermogenic properties when combined with other devices. Thermogenic gel packs and CWWB on high setting, both with and without reflective foil, caused significant temperature increases (that is, 1.6 °C to 4.4 °C) in mice. CWWB on medium setting (blanket temperature, 37.5 °C) maintained mice at temperatures within 1 °C of the 36.1 °C baseline. Strong correlations existed between temperature, heart and respiratory rates, and recovery time to consciousness. This information provides guidance regarding the use of thermoregulatory devices in anesthetized rodents and demonstrates the effect of maintaining a consistent core temperature on physiologic parameters.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3784664PMC

Publication Analysis

Top Keywords

reflective foil
20
thermoregulatory devices
12
cwwb high
12
high setting
12
temperature
10
mice
8
c57bl/6 mice
8
body temperature
8
temperature physiologic
8
physiologic parameters
8

Similar Publications

Lead-Free Perovskite CsAgNaBiInCl Microcrystals for Scattering-Fluorescent Luminescent Solar Concentrators.

ACS Appl Mater Interfaces

January 2025

Institute of Materials for Electronics and Energy Technology (i-MEET), Department of Materials Science and Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Martensstrasse 7, Erlangen 91058, Germany.

In recent years, luminescent solar concentrators (LSCs) have gained a renaissance as a pivotal transparent photovoltaic (PV) for building-integrated photovoltaics (BIPVs). However, most of the studies focused on light-selective LSCs, and less attention was paid to the utilization of the full solar spectrum. In this study, a lead-free microcrystal CsAgNaBiInCl (CANBIC) perovskite phosphor is demonstrated to have bifunctional effects of luminescent down-shifting (LDS) and light scattering for the fabrication of LSCs, realizing light response from ultraviolet (UV) to NIR regions by an edge-mounted Si solar cell.

View Article and Find Full Text PDF

Previous research has suggested the importance of relational language and working memory in children's relational reasoning. The tendency to use language (e.g.

View Article and Find Full Text PDF

Timing and/or position-sensitive MCP detectors, which detect secondary electrons (SEs) emitted from a conversion foil during ion passage, are widely utilized in nuclear physics and nuclear astrophysics experiments. This review covers high-performance timing and/or position-sensitive MCP detectors that use SE emission for mass measurements of exotic nuclei at nuclear physics facilities, along with their applications in new measurement schemes. The design, principles, performance, and applications of these detectors with different arrangements of electromagnetic fields are summarized.

View Article and Find Full Text PDF

The infra-red video bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of lines of sight within a large field of view. Recently validated in MAST-U [Fderici et al., Rev.

View Article and Find Full Text PDF

Facile Tailor on the Surface of Mo Foil Toward High-Efficient Flexible CZTSSe Solar Cells.

Small Methods

October 2024

Institute of Photoelectronic Thin Film Devices and Technology, State Key Laboratory of Photovoltaic Materials and Cell, and Engineering Research Center of Thin Film Optoelectronics Technology, Ministry of Education, Nankai University, Tianjin, 300350, China.

Article Synopsis
  • Flexible CuZnSn(S,Se) (CZTSSe) solar cells are gaining attention for their potential in various applications, but face issues with back interface problems when using Mo foil as a substrate.
  • A new method involving substrate polishing and UV-ozone treatment enhances the quality of the CZTSSe film and improves the interface quality, leading to better mechanical stability and efficient carrier collection.
  • As a result, the solar cell efficiency increased significantly from 4.94% to 10.32%, while also improving the bending durability of the cell.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!