The feasibility of delivering craniospinal irradiation (CSI) with TomoDirect is investigated. A method is proposed to generate TomoDirect plans using standard three-dimensional (3D) beam arrangements on Tomotherapy with junctioning of these fields to minimize hot or cold spots at the cranial/spinal junction. These plans are evaluated and compared to a helical Tomotherapy and a three-dimensional conformal therapy (3D CRT) plan delivered on a conventional linear accelerator (linac) for CSI. The comparison shows that a TomoDirect plan with an overlap between the cranial and spinal fields might be preferable over Tomotherapy plans because of decreased low dose to large volumes of normal tissues outside of the planning target volume (PTV). Although the TomoDirect plans were not dosimetrically superior to a 3D CRT linac plan, the patient can be easily treated in the supine position, which is often more comfortable and efficient from an anesthesia standpoint. TomoDirect plans also have only one setup position which obviates the need for matching of fields and feathering of junctions, two issues encountered with conventional 3D CRT plans. TomoDirect plans can be delivered with comparable treatment times to conventional 3D plans and in shorter times than a Tomotherapy plan. In this paper, a method is proposed for creating TomoDirect craniospinal plans, and the dosimetric consequences for choosing different planning parameters are discussed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5714580PMC
http://dx.doi.org/10.1120/jacmp.v14i5.4304DOI Listing

Publication Analysis

Top Keywords

tomodirect plans
16
plans
9
tomodirect
8
tomodirect craniospinal
8
craniospinal irradiation
8
method proposed
8
feasibility study
4
study tomodirect
4
irradiation feasibility
4
feasibility delivering
4

Similar Publications

Purpose: This study investigated the use of surface guided radiotherapy (SGRT) in combination with a tomotherapy treatment mode using discrete delivery angles for deep inspiration breath hold (DIBH) treatments of breast cancer (bc). We aimed to assess the feasibility and dosimetric advantages of this approach.

Materials And Methods: We evaluated camera occlusion in the Radixact treatment system bore and the stability of DIBH signals during couch movement.

View Article and Find Full Text PDF

Influence of the Planning Parameters of a New Algorithm on the Dosimetric Quality, Beam-On Time and Delivery Accuracy of Tomotherapy Plans.

Cancers (Basel)

May 2024

Medical Physics Unit, Institut de Cancerologie de Strasbourg (ICANS), 17 Rue Albert Calmette, 67200 Strasbourg, France.

Background: This work aimed to determine the optimum VOLO Ultra algorithm parameters for tomotherapy treatments.

Methods: 1056 treatment plans were generated with VOLO Ultra for 36 patients and six anatomical locations. The impact of varying four parameters was studied: the accelerated treatment (AT), leaf open/close time (LOT) cutoff, normal tissue objective (NTO) weight, and number of iterations.

View Article and Find Full Text PDF

Background/aim: To compare implant sparing irradiation with conventional radiotherapy (RT) using helical (H) and TomoDirect (TD) techniques in breast cancer patients undergoing immediate breast reconstruction (IBR).

Patients And Methods: The dosimetric parameters of 40 patients with retropectoral implants receiving 50.4 Gy delivered in 28 fractions were analyzed.

View Article and Find Full Text PDF

Background: The aim of the study was to perform dosimetric comparisons of helical (H) and TomoDirect (TD) plans for whole-breast irradiation (WBI) with simultaneous integrated boost (SIB) in early-stage breast cancer patients undergoing breast conserving surgery.

Materials And Methods: Fifty patients, 25 with left-side and 25 with right-side tumors, were determined for a treatment planning system for a total dose of 50.4Gy in 1.

View Article and Find Full Text PDF

The dose expansion methods as the skin flash and virtual bolus were used to solve intrafraction movement for breast planning due to breathing motion. We investigated the skin dose in each planning method by using optically stimulated luminescence on an in-house moving phantom for breast cancer treatment in tomotherapy. The impact of respiratory motion on skin dose between static and dynamic phantom's conditions was evaluated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!