Experimental study of underwater transmission characteristics of high-frequency 30 MHz polyurea ultrasonic transducer.

Ultrasonics

Precision and Intelligence Laboratory, Tokyo Institute of Technology, Nagatsuta-cho 4259, Midori-ku, Yokohama, Kanagawa 226-8503, Japan. Electronic address:

Published: February 2014

In this paper, we present the transmission characteristics of a polyurea ultrasonic transducer operating in water. In this study, we used a polyurea transducer with fundamental resonance at approximately 30 MHz. Firstly, acoustic pressure radiated from the transducer was measured using a hydrophone, which has a diameter of 0.2 mm. The transmission characteristics such as relative bandwidth, pulse width, and acoustic sensitivity were calculated from the experimental results. The results of the experiment showed a relative bandwidth of 50% and a pulse width of 0.061 μs. The acoustic sensitivity was 0.60 kPa/V with good linearity, where the correlation coefficient R in the fitting calculation was 0.996. A maximum pressure of 13.1 kPa was observed when the transducer was excited at a zero-to-peak voltage of 21 V. Moreover, we experimentally verified the results. The results of the pulse/echo experiment showed that the estimated diameters of the copper wires were 458 and 726 μm, where the differences between the actual and measured values were 15% and 4%, respectively. Acoustic streaming was also observed so that a particle velocity map was estimated by particle image velocimetry (PIV). The sound pressure calculated from the particle velocity obtained by PIV showed good agreement with the acoustic pressure measured using the hydrophone, where the differences between the calculated and measured values were 12-19%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultras.2013.08.006DOI Listing

Publication Analysis

Top Keywords

transmission characteristics
12
polyurea ultrasonic
8
ultrasonic transducer
8
acoustic pressure
8
measured hydrophone
8
relative bandwidth
8
pulse width
8
acoustic sensitivity
8
measured values
8
particle velocity
8

Similar Publications

3D Vertical Ferroelectric Capacitors with Excellent Scalability.

Nano Lett

January 2025

Division of Electronics and Electrical Engineering, Dongguk University, Seoul 04620, South Korea.

Three-dimensional vertically stacked memory is more cost-effective than two-dimensional stacked memory. Vertically stacked memory using ferroelectric materials has great potential not only in high-density memory but also in neuromorphic fields because it secures low voltage and fast operation speed. This paper presents the implementation of a ferroelectric capacitor comprising a vertical two-layer stacked structure composed of a titanium nitride (TiN)/aluminum-doped hafnium oxide/TiN configuration.

View Article and Find Full Text PDF

Pt ( = 1, 3, and 4) Cluster-Modified MoSe Nanosheets: A Potential Sensing and Scavenging Candidate for Lithium-Ion Battery State Characteristic Gases.

Langmuir

January 2025

State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China.

Realizing reliable online detection of characteristic gases (H, CH, CO, and CO) in lithium-ion batteries is crucial to maintain the safe and stable operation of power equipment and new energy storage power plants. In this study, transition metal Pt ( = 1, 3, and 4) clusters are attached to MoSe nanosheets for the first time based on density functional theory using the perfect crystalline facet modification method, and the adsorption characteristics and electronic behaviors of H, CH, CO, and CO are investigated and enhanced. The results show that Pt ( = 1, 3, and 4) is reliably chemically connected to the substrate without any significant deformation of the geometry.

View Article and Find Full Text PDF

Unlabelled: This study investigated the impact of the coronavirus disease 2019 (COVID-19) pandemic and its associated restrictive measures on infections in children with acute respiratory tract infection. The study aimed to elucidate the epidemiological characteristics of infections before and during the pandemic and following the easing of restrictive measures. Pharyngeal secretions were collected from 1,0174 pediatric patients with acute respiratory infection (ARI) who were admitted to Shaoxing Maternity and Child Health Care Hospital (Shaoxing, China) between May 2018 and December 2023.

View Article and Find Full Text PDF

Anisometric plasmonic nanoparticles find applications in various fields, from photocatalysis to biosensing. However, exposure to heat or to specific chemical environments can induce their reshaping, leading to loss of function. Understanding this process is therefore relevant both for the fundamental understanding of such nano-objects and for their practical applications.

View Article and Find Full Text PDF

Introduction: Opioid overdose and blood-borne virus transmission are key health risks for people who inject drugs. Existing study methods that record data on injecting drug risks mostly rely on retrospective self-reporting that, while valid, are limited to being broad and subject to recall bias. The In-The-Moment-Expanded (ITM-Ex) study will evaluate the feasibility and acceptability of multiple novel data collection methods to capture in situ drug injecting data.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!