Ultrasound tissue harmonic imaging is widely used to improve ultrasound B-mode imaging quality thanks to its effectiveness in suppressing imaging artifacts associated with ultrasound reverberation, phase aberration, and clutter noise. In ultrasound shear wave elastography (SWE), because the shear wave motion signal is extracted from the ultrasound signal, these noise sources can significantly deteriorate the shear wave motion tracking process and consequently result in noisy and biased shear wave motion detection. This situation is exacerbated in in vivo SWE applications such as heart, liver, and kidney. This paper, therefore, investigated the possibility of implementing harmonic imaging, specifically pulse-inversion harmonic imaging, in shear wave tracking, with the hypothesis that harmonic imaging can improve shear wave motion detection based on the same principles that apply to general harmonic B-mode imaging. We first designed an experiment with a gelatin phantom covered by an excised piece of pork belly and show that harmonic imaging can significantly improve shear wave motion detection by producing less underestimated shear wave motion and more consistent shear wave speed measurements than fundamental imaging. Then, a transthoracic heart experiment on a freshly sacrificed pig showed that harmonic imaging could robustly track the shear wave motion and give consistent shear wave speed measurements of the left ventricular myocardium while fundamental imaging could not. Finally, an in vivo transthoracic study of seven healthy volunteers showed that the proposed harmonic imaging tracking sequence could provide consistent estimates of the left ventricular myocardium stiffness in end-diastole with a general success rate of 80% and a success rate of 93.3% when excluding the subject with Body Mass Index higher than 25. These promising results indicate that pulse-inversion harmonic imaging can significantly improve shear wave motion tracking and thus potentially facilitate more robust assessment of tissue elasticity by SWE.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3947393 | PMC |
http://dx.doi.org/10.1109/TMI.2013.2280903 | DOI Listing |
Front Vet Sci
December 2024
Department of Anatomy, Faculty of Veterinary Medicine, Istanbul University-Cerrahpasa, Istanbul, Türkiye.
Introduction: This study aims to quantify the shear wave speed (SWS) and stiffness of the uterine cervix (close to the internal cervical ostium (IOC) which is the cranial portion of cervix and close to the external cervical ostium (EOC) which is the caudal portion of cervix), caruncular areas, and vulvar labia during the postpartum period in healthy Kivircik ewes by using shear-wave elastography. Power Doppler ultrasonography was performed to evaluate the color pixel percentage (CPP) of the caruncles.
Methods: The study included 13 healthy pregnant Kivircik ewes, which were randomly selected.
Ultrasound Med Biol
January 2025
Echosens, Paris, France.
Objective: Although FibroScan (FS), based on Vibration-Controlled Transient Elastography (VCTE), is a widely used non-invasive device for assessing liver fibrosis and steatosis, its current standard-VCTE examination remains timely and difficult on patients with obesity. The Guided-VCTE examination uses continuous shear waves to locate the liver by providing a real-time predictive indicator for shear wave propagation and uses shear wave maps averaging to increase the signal-to-noise ratio in difficult to assess patients. We aimed to evaluate the effectiveness of the new indicator, as well as compare examination times and success rates with both standard-VCTE and Guided-VCTE examinations.
View Article and Find Full Text PDFAcad Radiol
January 2025
Faculdade de Medicina e Ciências Biomédicas (FMCB), Universidade do Algarve. Campus de Gambelas, Edifício 2, 8005-139 Faro, Portugal (A.F.G., D.J., C.T., D.J., A.M., H.L.); Algarve Biomedical Center Research Institute (ABC-RI), Universidade do Algarve. Campus de Gambelas, Edifício 2, 8005-139 Faro, Portugal (A.M., E.P., H.L.).
Objective: The purpose of this systematic review and meta-analysis was comparing diagnostic performance of ultrasound elastography (UE), strain UE and shear wave elastography (SWE), with magnetic resonance imaging (MRI) in differentiating benign and malignant breast lesions.
Methods: Literature search of MEDLINE, Web of Science, SCOPUS and Google Scholar was performed in June 2023. Included studies used Breast Imaging Reporting and Data System (BI-RADS) and histopathology as reference standard.
Osteoarthr Cartil Open
March 2025
Graduate School of Health Sciences, Morinomiya University of Medical Sciences, Osaka, Japan.
Objective: To investigate whether there is a difference in hardness and hemoglobin concentration changes in the infrapatellar fat pad (IFP) during isometric quadriceps exercise (IQE) in patients with knee osteoarthritis (KOA) between those with and without knee extension limitation.
Design: In this cross-sectional study, data were collected at an orthopedic clinic from March 2022 to April 2023. Among patients diagnosed with KOA, those with knee joint extension range of motion <0° and >0° were defined as the limited group (n = 16) and non-limited group (n = 13), respectively.
Orthop Traumatol Surg Res
January 2025
Department of orthopedic surgery, Clinique du Sport, 36 Boulevard Saint-Marcel, 75005 Paris, France.
Background: Many techniques have been described for lateral ankle ligament reconstruction. Although the biomechanical properties of gracilis tendons are different from those of ligaments, the use of a gracilis tendon autograft is a popular option for anatomical reconstruction. Graft maturation and the biomechanical processes over time remain unclear.