Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 144
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3106
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Online monitoring of serotonin in striatal dialysate from freely moving rats was carried out for more than 16 h at 1 min time resolution using microdialysis coupled online to a capillary HPLC system operating at about 500 bar and 50 °C. Several aspects of the system were optimized toward robust, in vivo online measurements. A two-loop, eight-port rotary injection valve demonstrated better consistency of continuous injections than the more commonly used two-loop, 10-port valve. A six-port loop injector for introducing stimulating solutions (stimulus injector) was placed in-line between the syringe pump and microdialysis probe. We minimized solute dispersion by using capillary tubing (75 μm inside diameter, 70 cm long) for the probe inlet and outlet. In vitro assessment of concentration dispersion during transport with a 30 s time resolution showed that the dispersion standard deviation for serotonin was well within the desired system temporal resolution. Each 30 or 60 s measurement reflects the integral of the true time response over the measurement time. We have accounted for this mathematically in determining the concentration dispersion during transport. The delay time between a concentration change at the probe and its detection is 7 min. The timing of injections from the stimulus injector and the cycle time for the HPLC monitoring of the flow stream were controlled. The electrochemical detector contained a 13 μm spacer to minimize detector dead volume. During in vivo experiments, retention time and separation efficiency were stable and reproducible. There was no statistically significant change over 5.5 h in the electrochemical detector sensitivity factor for serotonin. Dialysate serotonin concentrations change significantly in response to a 120 mM K(+) stimulus. Release of serotonin evoked by a 10 min, 120 mM K(+) stimulation, but not for other K(+) stimuli, exhibited a reproducible, oscillating profile of dialysate serotonin concentration versus time. Infusion of fluoxetine, a serotonin uptake inhibitor, increased dialysate serotonin concentrations and stimulated release magnitude. Transient serotonin increases were observed in response to the stress associated with unexpected handling. This system is simple, efficient, reliable, and suitable for the study of serotonin neurochemistry associated with emotion and behavior.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3899587 | PMC |
http://dx.doi.org/10.1021/ac4023605 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!