There is a growing demand to integrate biosensors with microfluidics to provide miniaturized platforms with many favorable properties, such as reduced sample volume, decreased processing time, low cost analysis and low reagent consumption. These microfluidics-integrated biosensors would also have numerous advantages such as laminar flow, minimal handling of hazardous materials, multiple sample detection in parallel, portability and versatility in design. Microfluidics involves the science and technology of manipulation of fluids at the micro- to nano-liter level. It is predicted that combining biosensors with microfluidic chips will yield enhanced analytical capability, and widen the possibilities for applications in clinical diagnostics. The recent developments in microfluidics have helped researchers working in industries and educational institutes to adopt some of these platforms for point-of-care (POC) diagnostics. This review focuses on the latest advancements in the fields of microfluidic biosensing technologies, and on the challenges and possible solutions for translation of this technology for POC diagnostic applications. We also discuss the fabrication techniques required for developing microfluidic-integrated biosensors, recently reported biomarkers, and the prospects of POC diagnostics in the medical industry.

Download full-text PDF

Source
http://dx.doi.org/10.1002/biot.201200386DOI Listing

Publication Analysis

Top Keywords

microfluidic-integrated biosensors
8
poc diagnostics
8
biosensors prospects
4
prospects point-of-care
4
diagnostics
4
point-of-care diagnostics
4
diagnostics growing
4
growing demand
4
demand integrate
4
biosensors
4

Similar Publications

A self-driven, microfluidic, integrated-circuit biosensing chip for detecting four cardiovascular disease biomarkers.

Biosens Bioelectron

April 2024

Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, 30013, Taiwan; Institute of Nanoengineering and Microsystems, National Tsing Hua University, Hsinchu, 30013, Taiwan. Electronic address:

Cardiovascular diseases (CVDs) claimed the lives of nearly 21 million people worldwide in 2021, accounting for 30% of global deaths. However, one in five CVD patients is unaware that they have the disease, emphasizing the need for accurate biomarker monitoring. Herein we developed an integrated microfluidic system (IMS) for rapid quantification of four CVD biomarkers, including N-terminal pro B-type natriuretic peptide (NT-proBNP), fibrinogen, cardiac troponin I (cTnI), and C-reactive protein (CRP)- via aptamer-coated interdigitated electrodes (IDE) with integrated circuits (IC) and a self-driven IMS for sample treatment.

View Article and Find Full Text PDF

Background: Highly sensitive and rapid detection of cell concentration and interfacial molecular events is of great value for biological, biomedical, and chemical research. Most traditional biosensors require large sample volumes and complicated functional modifications of the surface. It is of great significance to develop label-free biosensor platforms with minimal sample consumption for studying cell concentration changes and interfacial molecular events without labor-intensive procedures.

View Article and Find Full Text PDF

Despite extensive advances in wearable monitoring systems, most designs focus on the detection of physical parameters or metabolites and do not consider the integration of microfluidic channels, miniaturization, and multimodality. In this study, a combination of multimodal (biochemical and electrophysiological) biosensing and microfluidic channel-integrated patch-based wireless systems is designed and fabricated using flexible materials for improved wearability, ease of operation, and real-time and continuous monitoring. The reduced graphene oxide-based microfluidic channel-integrated glucose biosensor exhibits a good sensitivity of 19.

View Article and Find Full Text PDF

Microbial pathogens have threatened the world due to their pathogenicity and ability to spread in communities. The conventional laboratory-based diagnostics of microbes such as bacteria and viruses need bulky expensive experimental instruments and skilled personnel which limits their usage in resource-limited settings. The biosensors-based point-of-care (POC) diagnostics have shown huge potential to detect microbial pathogens in a faster, cost-effective, and user-friendly manner.

View Article and Find Full Text PDF

Craft-and-Stick Xurographic Manufacturing of Integrated Microfluidic Electrochemical Sensing Platform.

Biosensors (Basel)

March 2023

Biosensors and Bioelectronics Centre, Division of Sensor and Actuator Systems, Department of Physics, Chemistry and Biology, Linköping University, SE-581 83 Linköping, Sweden.

An innovative modular approach for facile design and construction of flexible microfluidic biosensor platforms based on a dry manufacturing "craft-and-stick" approach is developed. The design and fabrication of the flexible graphene paper electrode (GPE) unit and polyethylene tetraphthalate sheet (PET)6/adhesive fluidic unit are completed by an economic and generic xurographic craft approach. The GPE widths and the microfluidic channels can be constructed down to 300 μm and 200 μm, respectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!