[Indication on the use of temporary ileostomy in extraperitoneal rectal surgery: is it still valid? Consideration on a case series].

Minerva Chir

Divisione Chirurgica 1°, Ospedale ValduceVia Dante 11, 22100 Como, Italy -

Published: August 2013

Download full-text PDF

Source

Publication Analysis

Top Keywords

[indication temporary
4
temporary ileostomy
4
ileostomy extraperitoneal
4
extraperitoneal rectal
4
rectal surgery
4
surgery valid?
4
valid? consideration
4
consideration case
4
case series]
4
[indication
1

Similar Publications

Background: Bicondylar tibial plateau fractures are often associated with significant soft tissue compromise making operative treatment challenging. Dual plating through a two-incision approach following temporary external fixation has been shown to improve complication rates although deep infection rates remain high.The objective was to evaluate early outcomes following a novel technique of percutaneous application of the medial plate superficial to the pes anserinus tendons.

View Article and Find Full Text PDF

Temporary Transvenous Pacing Performed in the Intensive Care Unit or in the Catheterization Laboratory.

Pacing Clin Electrophysiol

January 2025

Service de rythmologie cardiaque, Hôpital Cardiologique Louis Pradel, Hospices Civils de Lyon, Lyon, France.

Background: Temporary transvenous pacing (TTP) is a common procedure, predominantly performed in the catheterization laboratory (cath lab) because of presumed lower complication rate. This study aims to evaluate the efficacy and safety of TTP placement in the ICU compared to TTP placement in the cath lab.

Methods: This retrospective, real-life study included all patients requiring TTP in a tertiary care ICU between 2019 and 2022.

View Article and Find Full Text PDF

Purpose Of The Study: Temporary hemiepiphyseodesis using figure-eight plates is currently one of the main surgical techniques to correct axial deformities of lower limbs in paediatric patients. Comprehensive analysis, correct indication and monitoring of treatment are the basic prerequisites for successful therapy. The aim of the study was to analyse parameters that could become an alternative to standard parameters used nowadays, namely the inserted screw angle (SA), and a new parameter - condylar ratio (CR).

View Article and Find Full Text PDF

The use of temporary left ventricular assist devices (tLVADs) for patients suffering from cardiogenic shock (CS) is becoming more common. This study examines the indications and outcomes of microaxial flow pumps (Impella, Abiomed Inc., Danvers, MA, USA) when cannulated through the axillary artery in patients with severe CS, with a particular focus on acute phase reactions and hemolytic responses.

View Article and Find Full Text PDF

False Alarms in Wearable Cardioverter Defibrillators-A Relevant Issue or an Insignificant Observation.

J Clin Med

December 2024

Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité (DHZC), Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin, Germany.

The wearable cardioverter defibrillator (WCD) has emerged as a valuable tool used for temporary protection from sudden cardiac death. However, since the WCD uses surface electrodes to detect arrhythmias, it is susceptible to inappropriate detection. Although shock conversion rates for the WCD are reported to be high for detected events, its efficacy in clinical practice tends to be degraded by patient noncompliance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!