We investigated the impact of the preparation of reach movements on visual perception by simultaneously quantifying both an objective measure of visual sensitivity and the subjective experience of apparent contrast. Using a two-by-two alternative forced choice task, observers compared the orientation (clockwise or counterclockwise) and the contrast (higher or lower) of a Standard Gabor and a Test Gabor, the latter of which was presented during reach preparation, at the reach target location or the opposite location. Discrimination performance was better overall at the reach target than at the opposite location. Perceived contrast increased continuously at the target relative to the opposite location during reach preparation, that is, after the onset of the cue indicating the reach target. The finding that performance and appearance do not evolve in parallel during reach preparation points to a distinction with saccade preparation, for which we have shown previously there is a parallel temporal evolution of performance and appearance. Yet akin to saccade preparation, this study reveals that overall reach preparation enhances both visual performance and appearance.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3758200 | PMC |
http://dx.doi.org/10.1098/rstb.2013.0057 | DOI Listing |
Dent Mater
March 2025
Department of Conservative Dentistry and Periodontology, LMU University Hospital, LMU Munich, Goethestrasse 70, Munich 80336, Germany.
Objectives: The aim of this study was to examine the marginal seal of novel bioactive restorative materials and the material-related properties associated with bacterial microleakage.
Methods: Class II cavities prepared into human extracted teeth were restored with: Venus Diamond (VD) + selective enamel etching (SEE)/self-etching universal adhesive (SEA), ACTIVA BioACTIVE RESTORATIVE (AB) + SEE/SEA, Cention Forte (CF) + Cention Primer, Ketac Universal Aplicap (KU), EQUIA Forte HT (EF) and Surefil One (SO) and exposed to a cariogenic multi-species bacterial suspension for 7 days. Bacterial microleakage was visualized with a modified gram staining protocol and bacterial penetration depths were microscopically determined after sectioning the teeth.
Anal Chim Acta
May 2025
Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, Av. Diagonal 645, Barcelona, E-08028, Spain.
Background: Ambient Mass Spectrometry (AMS) encompasses a group of techniques that have emerged as powerful strategies for direct, in-situ and high-throughput analysis, also in compliance with the principles of green analytical chemistry. Swab Touch Spray-Mass Spectrometry (Swab TS-MS) is a home-made AMS technique that involves the use of a medical swab as sampling tool and electrospray probe. To date, Swab TS-MS has been applied only for the analysis of small molecules, especially in forensic and medical fields, leaving the analysis of peptides and proteins still unexplored.
View Article and Find Full Text PDFJ Prof Nurs
March 2025
Nursing Science department, Julius Center for Health Sciences and Primary Care, University Medical Centre Utrecht, Utrecht, the Netherlands; Nursing Science, Program in Clinical Health Sciences, University Medical Center Utrecht, Utrecht, the Netherlands.
Background: PhD prepared nurses advance nursing science through research and integration of findings into practice. They demonstrate expertise in research, education, patient care, and policy. Various professional competencies are required for success in research, clinical practice, and education.
View Article and Find Full Text PDFZhong Nan Da Xue Xue Bao Yi Xue Ban
October 2024
Xiangya Stomatological Hospital and Xiangya School of Stomatology, Central South University; Hunan Engineering Research Center for Digital Intelligence and Personalized Medicine; Hunan 3D Printing Engineering Research Center of Oral Care, Changsha 410008.
Objectives: Maxillary transverse deficiency is a common malocclusion frequently observed in orthodontic clinics. Miniscrew-assisted rapid palatal expansion (MARPE) not only produces greater skeletal expansion but also offers advantages such as simple miniscrew implantation without flap elevation, enhanced patient comfort, and an expanded age range and indications for palatal expansion. However, the fixed connection between the expander and the miniscrews makes the expander difficult to remove, significantly hindering its clinical application.
View Article and Find Full Text PDFInt J Biol Macromol
March 2025
School of Chemistry and Chemical Engineering Hainan University, Haikou 570228, Hainan Province, China; Key Laboratory of Bio-based Polymeric Materials Technology and Application of Zhejiang Province, Laboratory of Polymers and Composites, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, Zhejiang Province, China. Electronic address:
The synthesis of monomers with two epoxy structures (EIA) was successfully achieved by adopting holo-biobased feedstocks and in situ solvolysis reaction. The molecular structure of EIA was subjected to characterization through the use of infrared spectroscopy (IR), mass spectrometry (MS), and nuclear magnetic resonance hydrogen spectroscopy (H NMR). The EIA was employed as the epoxy monomers for the synthesis of the grafted compatibilizer, resulting in the successful preparation of a fully bio-based and high epoxy value grafted compatibilizer (PLA-g-EIA (PLE)).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!