This work presents the development of a new design for a membraneless vaporization (MBL-VP) unit, called dual chamber MBL-VP for measurement of volatile compounds. With this unit, exact volumes of sample and reagent are introduced into their respective cone-shaped chambers from the base of the cones. Diffusion of volatile analyte then takes place. After an appropriate time interval, the acceptor solution is withdrawn from the chamber into the detector flow-cell, while the sample solution is withdrawn to waste. Unlike the previous MBL-VP design, problems with overflow of solutions are eliminated by precise control of the input volume to be less than the volume of the chamber. The developed flow system with the dual chamber MBL-VP unit was applied to the determination of the ethanol content of various liquid samples, using the oxidation reaction between potassium dichromate and the diffused ethanol. In addition, in order to accelerate the gas diffusion process, the donor chamber was aerated. As the result, relatively short analysis time of 144 s was achieved for ethanol content in the range of 5-50% (v/v). The proposed method was successfully validated against a gas chromatographic method for 17 alcoholic samples. Percentage recovery was in the range of 96-109%.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.aca.2013.07.072 | DOI Listing |
Anal Chim Acta
February 2024
Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki, 54124, Greece. Electronic address:
Herein, the proof-of-concept of a novel lab-in-syringe (LIS) foam microextraction platform is presented as a front-end to cold vapor atomic absorption spectrometry (CVAAS) for the simultaneous preconcentration and membraneless gas-liquid separation (GLS) of inorganic mercury in biological samples. The proposed method is based on the on-line formation of the ammonium pyrrolidine dithiocarbamate complex with mercury that was retained in the pores of polyurethane foam immobilized on the piston of the LIS system. Metal complex elution and in situ mercury vapor generation are accomplished inside the microsyringe in a flow-batch format, while the separation of vapor species is achieved via the membraneless GLS found at the top of the syringe's barrel.
View Article and Find Full Text PDFACS Sens
April 2023
Department of Chemistry, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea.
Development of sensing technologies for trace vapors of nitroaromatic compounds (NACs) is highly desired due to the toxic and explosive nature of the target molecules. Here, a NAC sensor based on a membraneless ionic liquid electrochemical cell was developed and applied for room-temperature trace vapor detection. Submicrometer working electrode dimensions yielded maximized portability and cost efficiency and extremely short time scales for molecular identification.
View Article and Find Full Text PDFWater Res
February 2023
State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin 150090, China.
Treatment of recalcitrant landfill leachate (LFL) induces huge energy consumption and carbon emissions due to its complex composition. Although membrane distillation (MD) exhibits good potential in LFL treatment with waste heat utilization, membrane fouling and ammonia rejection are still the major problems encountered that hinder its application. Herein, membrane electrochemical reactor (MER) was coupled with MD for simultaneous membrane fouling control and resource recovery.
View Article and Find Full Text PDFJ Anal Methods Chem
March 2022
Department of Chemistry, Faculty of Natural Sciences, National University of Laos, P.O. Box 7322, Vientiane, Laos.
This work utilized the simplicity of a so-called membraneless vaporization (MBL-VP) unit as a gas separator for the colorimetric determination of ethanol in alcoholic beverages. A beverage sample with a volume of 1 mL was directly injected into a small container which was hung from a lid inside a closed 40 mL reused glass bottle without pretreatment such as distillation. An acidified potassium dichromate (CrO ) acceptor solution, preadded to the glass bottle, was reduced to Chromium (III) ion by the diffusion of vaporized ethanol from the sample.
View Article and Find Full Text PDFAnal Methods
January 2021
Department of Chemistry, University of the Balearic Islands, 07122 Palma de Mallorca, Spain.
A new design of a membraneless vaporization (MBL-VP) unit coupled with a specific flow system is presented for the determination of arsenic at trace levels using a hydride generation process. The MBL-VP unit contains two concentric conical reservoirs, with the outer cone selected as the donor reservoir. The volume of the outer donor reservoir is thereby greater than the acceptor volume, necessary for holding sufficient sample and reagents for the generation of arsine gas by reaction between As(iii) and sodium borohydride under acidic conditions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!