Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Based on the semipermeability of hollow fiber membranes, a post-column membrane reactor was developed for capillary electrophoresis (CE)-laser induced fluorescence (LIF) analysis of proteins by using a hollow fiber membrane to connect the separation and detection capillaries. The membrane length between the separation and detection capillaries was 1 mm. Driven by the chemical potential difference between the separation buffer inside the membrane and the fluorescence derivatization solution outside the membrane, the derivatization reagent can be easily drawn into hollow fiber membrane to react with proteins. Also, the separation buffer can be adjusted by the derivatization solution to match the conditions of derivatization without sample loss. The effect of the separation buffer on the derivatization reaction was investigated and the results showed that even a strong acidic solution and multiple additives can be adopted in the separation buffer without destroying the post-column derivatization of proteins. Under the optimized conditions, the highly sensitive detection of BSA was achieved with a detection limit of 3.3 nmol L(-1) and a linear calibration range from 0.007 to 0.1 mg mL(-1). The proposed CE-LIF system with a post-column membrane reactor was also successfully applied to the separation and detection of proteins in rat liver and loach muscle.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/c3an00953j | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!